PRELIMINARY
USBDEVELKIT DEVELOPMENT KIT V3
USBDEVELKIT DEVELOPMENT KIT V3_001 www.meas-spec.com August 8, 2013
000USBDK2034 ECN1444 2/5
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Conditions Min Max Unit Notes
NOTE
1) Storage and operation in an environment of dry and non-corrosive gases.
RECOMMANDED OPERATION CONDITIONS
(Ta = 25°C, VDD = 3.0 V unless noted otherwise)
Parameter Symbol Conditions Min. Typ. Max Unit
Supply voltage VDDUSB 5.0 V
Active
I
Active
I
Idle
13.5
4
mA
mA
Update speed.
performance may vary
1 25 Hz
Operating temperature
range
T 0 +25 +50 °C
Internal Self Test Key P_error +/-5 mBar
FUNCTION
GENERAL
The USB DEVEL module is meant for evaluation of new and future pressure sensor modules from MEAS
Switzerland Sàrl.
The module and software will allow the user to see the raw and calibration data read from the sensor as well the
calculated pressure and altitude derived from those data.
HUMIDITY, WATER PROTECTION
The USB DEMO module case does not provide special water protection.
LIGHT SENSITIVITY
The USB DEMO module should provide adequate light protection for most indoor and outdoor lightning
situations.
ESD PRECAUTIONS
Some ESD suppressor diodes help protect against the risks due to electrostatic discharges on the USB port
connectors up to 2kV direct discharge.