ICS601-25
LOW PHASE NOISE 1 TO 5 CLOCK MULTIPLIER CLOCK MULTIPLIER
IDT™ / ICS™
LOW PHASE NOISE 1 TO 5 CLOCK MULTIPLIER 3
ICS601-25 REV D 102709
External Components
The ICS601-25 requires a minimum number of external components for proper operation. Decoupling capacitors of
0.01 µF and 0.1 µF should be connected between VDD and GND, as close to the part as possible. A 33Ω series
terminating resistor should be used on each clock output. The crystal must be connected as close to the chip as
possible. The crystal should be fundamental mode, parallel resonant. Do not use third overtone. For exact tuning
when using a crystal, capacitors should be connected from pins X1 to ground and X2 to ground. In general, the
value of these capacitors is given by the following equation, where CL is the crystal load capacitance: Crystal caps
(pF) = (CL-5) x 2. So for a crystal with 16 pF load capacitance, two 22 pF caps can be used. For any given board
layout, ICS can measure the board capacitance and recommend the exact capacitance value to use.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS601-25. These ratings, which are
standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these
or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Recommended Operation Conditions
DC Electrical Characteristics
VDD=3.3 V ±10%, Ambient temperature -40 to +85° C
Item Rating
Supply Voltage, VDD 7 V
All Inputs and Outputs -0.5 V to VDD+0.5 V
Ambient Operating Temperature, Commercial version 0 to +70 ° C
Ambient Operating Temperature, Industrial version -40 to +85 ° C
Storage Temperature -65 to +150 ° C
Junction Temperature 125 ° C
Soldering Temperature 260 ° C
Parameter Min. Typ. Max. Units
Ambient Operating Temperature (commercial) 0 +70 ° C
Ambient Operating Temperature (industrial) -40 +85 ° C
Power Supply Voltage (measured in respect to GND) +2.97 +3.63 V
Parameter Symbol Conditions Min. Typ. Max. Units
Operating Voltage VDD 2.97 3.63 V
Input High Voltage V
IH
X1/ICLK pin only VDD/2+1 V
Input Low Voltage V
IL
X1/ICLK pin only VDD/2-1 V