DS26014 Rev. 4 - 2 1 of 3 PR3001 - PR3005
www.diodes.com ã Diodes Incorporated
PR3001 - PR3005
3.0A FAST RECOVERY RECTIFIER
Features
DO-201AD
Dim Min Max
A
25.40 ¾
B
7.20 9.50
C
1.20 1.30
D
4.80 5.30
All Dimensions in mm
Maximum Ratings and Electrical Characteristics
@ T
A
= 25°C unless otherwise specified
· Diffused Junction
· Fast Switching for High Efficiency
· Surge Overload Rating to 150 A Peak
· Low Reverse Leakage Current
· Lead Free Finish, RoHS Compliant (Note 4)
Mechanical Data
· Case: DO-201AD
· Case Material: Molded Plastic. UL Flammability
Classification Rating 94V-0
· Moisture Sensitivity: Level 1 per J-STD-020C
· Terminals: Finish - Tin. Plated Leads Solderable per
MIL-STD-202, Method 208
· Polarity: Cathode Band
· Marking: Type Number
· Ordering Information: See Page 3
· Weight: 1.12 grams (approximate)
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Characteristic Symbol
PR
3001
PR
3002
PR
3003
PR
3004
PR
3005
Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage (Note 5)
V
RRM
V
RWM
V
R
50 100 200 400 600 V
RMS Reverse Voltage
V
R(RMS)
35 70 140 280 420 V
Average Rectified Output Current
(Note 1) @ T
A
= 90°C
I
O
3.0 A
Non-Repetitive Peak Forward Surge Current
8.3ms Single half sine-wave Superimposed on Rated Load
I
FSM
150 A
Forward Voltage @ I
F
= 3.0A
V
FM
1.2 V
Peak Reverse Current @ T
A
= 25°C
at Rated DC Blocking Voltage (Note 5) @ T
A
= 100°C
I
RM
5.0
100
mA
Reverse Recovery Time (Note 3)
t
rr
150 250 ns
Typical Total Capacitance (Note 2)
C
T
50 pF
Typical Thermal Resistance Junction to Ambient
R
qJA
15 °C/W
Operating and Storage Temperature Range
T
j,
T
STG
-65 to +150 °C
Notes: 1. Valid provided that leads are maintained at ambient temperature at a distance of 9.5mm from the case.
2. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
3. Measured with I
F
=0.5A, I
R
= 1.0A, I
rr
= 0.25A. See figure 5.
4. RoHS revision 13.2.2003. High temperature solder exemption applied, see EU Directive Annex Note 7.
5. Short duration pulse test used to minimize self-heating effect.