TL-TTL-T
J EFFECT OF S URROUNDING METALS
If the T L-T5M i s embedded in metal, keep at least the following
distances between the TL-T and the metal.
If the T L-T2 i s embedded in
metal, the TL-T2 will not be
influenced by metal.
15 mm (0.59)
25 mm (0.98)
12 mm
(0.47)
15 mm 15 mm
15 mm (0.59)
15 mm (0.59)
J MUTUAL INTERFERENCE
When two or more T L-T sensors are mounted face-to-face or side-
by-side, separate them as shown below. The table below indicates
the minimum distances A and B.
AB
Distance A B
TL-T5jj 120 mm (4.72 i n) 80 mm (3.15 in)
TL-T5jj5 60 mm (2.36 in) 40 mm (1.57 in)
TL-T2jj 40 mm (1.57 in) 12 mm (0.47 in)
TL-T2jj5 10 mm (0.39 in) 0mm
Note: Figures in parentheses will apply if the Sensors in use are
different from each other in response frequency.
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
R
OMRON ON--LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci