TL-T2F2

TL-TTL-T
4
En
g
ineerin
g
Data
TL-T5M
TL-T5M standar d object:
Ironwith15x15xt1in
size)
TL-T2 standard object:
Ironwith12x12xt1in
size)
Sensing head
Sensing distance X (mm)
Sensing distance X (mm)
Steel
Stainless steel
(SUS304)
Brass
Aluminum
Side length of sensing object: d (mm)
Steel
Stainless steel (SUS304)
Brass
Aluminum
Side length of sensing object: d (mm)
J OPERATING RANGE
(TYPICAL)
J
SENSING OBJECT SIZE AND MA TERIAL VS. SENSING
DISTANCE (TYPICAL)
Sensing distance X (mm)
TL-T2
(at constant 200 VAC)
Load voltage V (V)
L
Load current
(
mA
)
Load voltage V (V)
L
Load current
(
mA
)
AC
power
supply
Su
p
p
l
y
volta
g
e
(
V
)
J LEAKAGE CURRENT
(TYPICAL)
J RESIDUAL LOAD VOLTAGE (TYPICAL)
Leakage current (mA)
100 VAC
200 VAC
TL-TjY
(at constant 100 VAC)
TL-T
TL- T
5
Dimensions
Unit: mm (inch)
Sensing
surface
Indicator
Two, 3.1 dia. (0.122)
Tw o , M 3 ,
depth 6
DC switching model: Three, 0.2-mm (0.007 in) conductors
AC switching model: Two, 0.3-mm (0.012 in) conductors
Oil- and vibration-resistant, vinyl-insulated round cord,
4 external dia.; standard length: 2 m (6.56 ft)
6 (0.24)
40
(1.57)
4
26
(1.02)
4
5 (0.19)
9 (0.35)
12
(0.47)
17
¦
0.2
(0.787
¦
0.008
)
16
¦
0.2
(0.0.63
¦
0.008
)
32
¦
0.2
(1.259
¦
0.008
)
Precautions
J CONNECTION TO THE LOAD
Be sure to connect the Proximity S ensor to the power source
through a load. Direct connection of the Sensor may damage the
Sensor.
Load
90 to 250 VAC
J MOUNTING
At the time of rear mounting, be sure that the tightening torque
does not exceed 6 kgf S cm (0.59 N S m) 5.22 in S lbf.
Mounting screws, each tight-
ened to torque 6 kgf S cm
(0.59 N S m) max.
At the time of side mounting, be sure that the tightening torque
does not exceed 8 kgf S cm (0.78 N S m) 2.02 in S lbf.
Mounting screws, each tight-
ened to torque 8 kgf S cm
(0.78 N S m) max.
TL-TTL-T
J EFFECT OF S URROUNDING METALS
If the T L-T5M i s embedded in metal, keep at least the following
distances between the TL-T and the metal.
If the T L-T2 i s embedded in
metal, the TL-T2 will not be
influenced by metal.
15 mm (0.59)
25 mm (0.98)
12 mm
(0.47)
15 mm 15 mm
15 mm (0.59)
15 mm (0.59)
J MUTUAL INTERFERENCE
When two or more T L-T sensors are mounted face-to-face or side-
by-side, separate them as shown below. The table below indicates
the minimum distances A and B.
AB
Distance A B
TL-T5jj 120 mm (4.72 i n) 80 mm (3.15 in)
TL-T5jj5 60 mm (2.36 in) 40 mm (1.57 in)
TL-T2jj 40 mm (1.57 in) 12 mm (0.47 in)
TL-T2jj5 10 mm (0.39 in) 0mm
Note: Figures in parentheses will apply if the Sensors in use are
different from each other in response frequency.
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A
.
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
R
OMRON ON--LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci

TL-T2F2

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Proximity Sensors MINI FLAT PROX 2MM PNP NC SHLD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union