Turquoise Stroke Mini Switches (ASQM1)
–2–
AECTB55E 201701-T
SPECIFICATIONS
■ Contact rating
1 mA 5 V DC to 50 mA 16 V DC
■ Operation environment and conditions
Note: When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly
depending on the load capacity. Please consult us.
■ Electrical characteristics
■ Characteristics
Notes: As long as there are no particular designations, the following conditions apply to the test environment.
• Ambient temperature: 5 to 35°C
• Relative humidity: 25 to 85% RH
• Air pressure: 86 to 106 kPa
■ Protection grade
Item Specifications
Ambient and storage temperature –40°C to +85°C (no freezing and condensing)
Allowable operating speed 30 to 500 mm/sec.
Max. operating cycle rate 120 cpm
Item Specifications
Dielectric strength (Initial)
Between non-continuous terminals: 500 Vrms, Between each terminal and other exposed metal parts: 1,500 Vrms,
Between each terminal and ground: 1,500 Vrms (at detection current of 1 mA)
Insulation resistance (Initial) Min. 100 MΩ (at 500 V DC insulation resistance meter) (Locations measured same as dielectric strength.)
Contact resistance (Initial) Max. 500 mΩ (by voltage drop 50 mA 6 to 8 V DC)
Item Specifications
Electrical
switching life
5 V DC 1 mA (Resistive load) Min. 3 × 10
5
Switching frequency: 20 times/min.
Conduction ratio: 1:1
Plunger operation speed: 100 mm/s
Plunger switching position: Free Position (FP) to Total Travel Position (TTP)
12 V DC 50 mA (Resistive load) Min. 2 × 10
5
16 V DC 50 mA (Resistive load) Min. 1.5 × 10
5
Vibration resistance
(malfunction vibration resistance)
Single amplitude: 0.75 mm
Amplitude of vibration: 10 to 55 Hz (4 minutes cycle)
Direction and time: 30 minutes each in X, Y and Z directions
Amplitude of vibration: 5 to 200 Hz (10 minutes cycle)
Acceleration: 43.1 m/s
2
Direction and time: 30 minutes each in X, Y and Z directions
Shock resistance
(malfunction shock resistance)
Shock value: 980 m/s
2
Direction and time: 5 times each in X, Y and Z directions
Terminal strength Min. 6 N (each direction) *Terminal deformation possible.
Heat resistance 85°C 500 hours
Cold resistance –40°C 500 hours
Humidity resistance 40°C 95% RH 500 hours
Unit weight Approx. 0.5 g (Terminal type), Approx. 3.9 g (Wire leads type)
Protection grade IP67 (except exposed terminal part of terminal type)
1) JIS C0920 (water-resistance experiments for electrical
machines and protection rating against incursion of solid
substances): Immersion protected (Note 1)
2) IEC 60529 (rating for outer shell protection): IP67 (Immersion
protected) (Note 1)
except metal terminal part (See below drawing)
3) JIS D0203 (method for testing moisture resistance and water
resistance in automotive components): Equivalent of D2 (Note 2)
Note 1) A concrete testing method is to check for any adverse effect on the structure
after leaving it submerged for 30 minutes under 1 m of water (with
temperature difference between water and switch no larger than 5°C).
Note 2) A concrete testing method is to check for any adverse effect on the structure
after leaving it submerged for 10 minutes under 10 cm water (with
temperature difference between water and switch no larger than 30°C).
Metal terminal part