2987079

© PHOENIX CONTACT 2012-10-29
103119_en_02
PLC-RSP…21HC/RW
Data Sheet
1Description
The 14 mm slim relay series PLC-RSP…21HC/RW has
been especially developed for railway applications and is
certified according to EN 50155. The modules available with
input voltages of 24 V, 72 V and 110 V (further voltages on
request) meet the trend towards energy, weight, and space
saving in railway technology.
1.1 Wide-range Electronics Minimize Self-heating
In contrast to other manufacturer's relay modules
PLC-RSP…21HC/RW has a special wide-range input
voltage, similar to those in switched-mode power supply
units, offering considerable advantages:
Control voltage range from 70 % to 125 % of the
nominal voltage throughout the entire temperature and
loadrange
Very low self-heating even with increased control
voltage
Wider ambient temperature range from -40 °C to
+70 °C throughout the entire control voltage and load
range
Furthermore, the modules are equipped with an RCZ filter
and surge protection on the input side, to ensure high
operational safety and resistance to interference.
Make sure you always use the latest documentation.
It can be downloaded at www.phoenixcontact.net/catalog
.
This data sheet is valid for all products listed on the following page:
PLC-INTERFACE With 1 PDT Relay for Railway
Applications in Accordance With EN 50155,
High-current Version
PLC-RSP…21HC/RW
103119_en_02 PHOENIX CONTACT 2
1.2 Robust 1 PDT Relay for High Loads
The abbreviation "HC" in the designation stands for "High
Current" applications, up to 10 A continuous current. The
block contains a 16-A power relay with PDT contact
application, so that additional reserves are used if
overdimensioning occurs, e. g. with short-term overloads.
The relay is secured against vibration by a retaining bracket
and can be exchanged if it becomes worn, without removing
the wiring. The relay is sealed in accordance with degree of
protection RTII to protect the relay mechanics against
external influences such as dust.
1.3 Vibration-resistant Plug-in Bridge System
Reduces the Wiring
Another feature of the PLC series is the FBST 500 plug-in
bridge system that can be cut to any length: It can be
plugged into the control and/or contact side "with a click"
and snapped into place to ensure a vibration-free
connection. Up to 35 PLCs can be clearly connected "to the
block" within seconds, without any errors.
1.4 Additional PLC Advantages
Marking labels from the standard modular terminal
block range
Many other electromechanical relays and electronic
solid-state relays are available in the PLC series
Quick, polarized connection of eight PLCs with control
via PLC-V8 adapter and system cable
High-quality, vibration proof Phoenix Contact
connection method
2Ordering Data
PLC-INTERFACE With Power Contact
Description Type Order No. Pcs./Pck.
PLC-INTERFACE with 1 PDT relay for railway applications in accordance with
EN 50155, input voltage 24 V DC, high-current version
PLC-RSP- 24UC/21HC/RW 2987079 10
PLC-INTERFACE with 1 PDT relay for railway applications in accordance with
EN 50155, input voltage 72 V DC, high-current version
PLC-RSP- 72UC/21HC/RW 2987082 10
PLC-INTERFACE with 1 PDT relay for railway applications in accordance with
EN 50155, input voltage 110 V DC, high-current version
PLC-RSP-110UC/21HC/RW 2987095 10
Accessories
Description Type Order No. Pcs./Pck.
Partition plate PLC-ATP BK 2966841 25
Further accessories such as power terminal and plug-in bridges can be found in the INTERFACE catalog and at www.phoenixcontact.net/catalog.
Partition plate PLC-ATP BK is to be used in the following cases: always fit at the start and end of a PLC terminal strip for voltages greater
than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (FBST 8-PLC... or FBST 500... can be used for potential
bridging) and for safe isolation between adjacent modules.
PLC-RSP…21HC/RW
103119_en_02 PHOENIX CONTACT 3
3 Technical Data
Input Data PLC-...24UC... PLC-...72UC... PLC-...110UC...
Nominal input voltage U
N
24 V DC 72 V DC 110 V DC
Permissible range (with reference to U
N
) 0.7 ... 1.25 x U
N
Typical input current at U
N
12 mA 5,9 mA 4 mA
Typical response time at U
N
8 ms
Typical release time at U
N
11 ms
Input circuit LED, wide-range electronics, free-wheeling diode,
surge protection, bridge rectifier, RCZ filter
Output Data
Contact type Single contact, 1 PDT
Contact material AgNi
Maximum switching voltage 250 V AC/DC
1
Minimum switching voltage 12 V AC/DC
Limiting continuous current 10 A with inserted plug-in bridge FBST 14-PLC BK (Order No. 2967691)
Maximum inrush current 30 A (300 ms)
Minimum switching current 10 mA
Maximum power rating
24 V DC
48 V DC
60 V DC
110 V DC
220 V DC
250 V AC
Ohmic load t = 0 ms
240 W
58 W
48 W
50 W
75 W
2500 VA
1
The PLC-ATP BK partition plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
General Data
Rated surge voltage 6 kV
Ambient temperature range -40 °C... 70 °C (temperature class TX)
Nominal operating mode 100% operating factor
Inflammability class according to UL 94 (housing) V0
Mechanical service life 3 x 10
7
cycles
Air and creepage distances between circuits DIN EN 50178 (safe isolation: control/contact side)
Pollution degree 2
Surge voltage category III
Mounting position Any
Installation location/category On vehicle body/category 1, class B
Mounting Can be aligned without spacing
Connection method Spring-cage connection
Conductor Cross Section
Solid
Stranded
0.2 mm
2
... 2.5 mm
2
0.2 mm
2
... 2.5 mm
2
Dimensions (W x H x D) 14 mm x 94 mm x 80 mm
Housing material Polybutylene terephthalate PBT non-reinforced, green
Tests/Approvals
EN 50155, EN 61373, EN 50121 Yes
CE
c
UL, GL
  

2987079

Mfr. #:
Manufacturer:
Phoenix Contact
Description: