Data Sheet ADM6384
Rev. D | Page 3 of 12
SPECIFICATIONS
V
CC
= full operating range, T
A
= −40°C to +125°C, unless otherwise noted.
Table 1.
Parameter Min Typ Max Unit Test Conditions/Comments
SUPPLY
CC
Supply Current 7 13 µA V
CC
= 5.5 V, no load
6 11 µA V
CC
= 3.6 V, no load
4 7 µA V
CC
= 2.5 V, no load
1
3 6 µA V
CC
= 1.8 V, no load
1
RESET THRESHOLD VOLTAGE
ADM6384x50x 4.88 5.00 5.12 V
ADM6384x49x 4.78 4.90 5.02 V
ADM6384x47x 4.58 4.70 4.82 V
ADM6384x46x 4.51 4.63 4.74 V
ADM6384x45x 4.39 4.5 4.61 V
ADM6384x44x 4.27 4.38 4.48 V
ADM6384x43x 4.19 4.30 4.41 V
ADM6384x41x 4.0 4.1 4.2 V
ADM6384x40x 3.9 4.0 4.1 V
ADM6384x39x 3.8 3.9 4.0 V
ADM6384x38x 3.71 3.8 3.9 V
ADM6384x36x 3.51 3.6 3.69 V
ADM6384x35x 3.41 3.5 3.59 V
ADM6384x34x 3.32 3.4 3.49 V
ADM6384x33x 3.22 3.3 3.38 V
ADM6384x32x 3.12 3.2 3.28 V
ADM6384x30x 2.93 3.0 3.08 V
ADM6384x29x 2.85 2.93 3.00 V
ADM6384x28x 2.73 2.8 2.87 V
ADM6384x27x 2.63 2.70 2.77 V
ADM6384x26x 2.56 2.63 2.69 V
ADM6384x25x 2.44 2.5 2.56 V
ADM6384x24x 2.34 2.4 2.46 V
ADM6384x23x 2.26 2.31 2.37 V
ADM6384x22x 2.13 2.19 2.24 V
ADM6384x17x 1.62 1.67 1.71 V
RESET THRESHOLD TEMPERATURE COEFFICIENT 60 ppm/°C
V
CC
to Reset Delay 35 µs
V
CC
falling at 10 mV/µs from V
TH
+
100 mV to V
TH
− 100 mV
RESET THRESHOLD HYSTERESIS 2 × V
TH
mV
RESET TIMEOUT PERIOD
ADM6384xxD1 1 2 ms
ADM6384xxD2 20 40 ms
ADM6384xxD3 140 280 ms
ADM6384xxD4 1120 2240 ms