A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet – MK07 Reed Sensors
www.standexmeder.com
MK07 Series
Reed Sensors
Features: Threaded Reed Sensor, Choice of Cable Termination & Lengths available, Various Case Sizes
Applications: Door & Window Contacts, Position and Limit Switch, Level Sensor (with Magnetic Float)
Markets: Appliance, Industrial, Security & Others
Modifications in the sense of technical progress are reserved.
Description: MK 07- 0 X 00X - 000X
Switch
Model
Magnetic
Sensitivity
Cable Length
(mm)
1 A, B 66, 85, 90 B, C, D, E
100, 200, 300, 500,
1,000, 1,500
W
Options
Switch Model
Unit
66 85 90
(max.)
DC combination of V&A not to exceed their individual max.’s
10 100 10 W
(max.)
peak AC
200 1000 175 V
(max.)
or peak AC
0.5 1 0.5 A
(max.)
or peak AC
1.0 2.5 1.0 A
(max.)
0.5V & 50mA
150 150 150 mOhm
Voltage (min.)
to EN60255-5
0.25
1.5 0.2 kVDC
Time (max.)
Incl. Bounce; Measured with w/ Nominal Voltage
0.7 1.1 0.7 ms
with no Coil Excitation
0.05 0.05 1.5 ms
Resistance (typ.)
%, 100V Test Voltage
10
10
10
10
10
9
Ohm
(typ.)
10kHz across open Switch
0.3 0.5 1.5 pF
Version 01
27.01.2015
USA: +1.866.782.6339 │ salesusa@standexmeder.com
Europe: +49.7731.8399.0 │ info@standexmeder.com
Asia: +86.21.37820625 │ salesasia@standexmeder.com