PCB Relay G5LB 635
■ Coil Ratings
360-mW Type
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
400-mW Type
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
600-mW Type
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Contact Ratings
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 36 VDC 48 VDC
Rated current 123.3 mA 72.0 mA 60.8 mA 40.8 mA 30.7 mA 15.2 mA 10.2 mA 7.6 mA
Coil resistance 24.3 Ω 69.4 Ω 98.7 Ω 220.4 Ω 390.6 Ω 1575.4 Ω 3533.7 Ω 6287.4 Ω
Must operate voltage 75% of rated voltage (max.)
Must release voltage 10% of rated voltage (min.)
Max. voltage 130% of rated voltage at 85°C, 170% of rated voltage at 23°C
Power consumption Approx. 360 mW
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 36 VDC 48 VDC
Rated current 136.4 mA 80.0 mA 67.8 mA 45.7 mA 32.8 mA 17.0 mA 11.3 mA 8.5 mA
Coil resistance 22.0 Ω 62.5 Ω 88.5 Ω 196.9 Ω 366.0 Ω 1,407.7 Ω 3,196.8 Ω 5,638.0 Ω
Must operate voltage 75% of rated voltage (max.)
Must release voltage 10% of rated voltage (min.)
Max. voltage 130% of rated voltage at 85°C, 170% of rated voltage at 23°C
Power consumption Approx. 400 mW
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 36 VDC 48 VDC
Rated current 200.2 mA 120.0 mA 100.7 mA 66.8 mA 50.4 mA 25.3 mA 16.6 mA 12.6 mA
Coil resistance 15.0 Ω 41.7 Ω 59.6 Ω 134.8 Ω 237.9 Ω 947.6 Ω 2,164.8 Ω 3,800.0 Ω
Must operate voltage 75% of rated voltage (max.)
Must release voltage 10% of rated voltage (min.)
Max. voltage 130% of rated voltage at 85°C, 170% of rated voltage at 23°C
Power consumption Approx. 600 mW
Load Resistive load (cos Ø = 1)
Rated load 10 A at 120 VAC; 8 A at 30 VDC & 10A at 250 VDC
Rated carry current 10 A
Max. switching voltage 250 VAC, 125 VDC (30 VDC when UL/CSA standard is applied)
Max. switching current AC: 10A; DC: 8A
Max. switching capacity 1,200 VA, 240 W & 2,500 VA
Min. permissible load 100 mA at 5 VDC