Data Sheet ADGS1408/ADGS1409
Rev. 0 | Page 9 of 34
Parameter +25°C −40°C to +85°C −40°C to +125°C Unit Test Conditions/Comments
C
D
(On), C
S
(On) V
S
= 6 V, f = 1 MHz
ADGS1408 170 pF typ
ADGS1409 110 pF typ
POWER REQUIREMENTS V
DD
= 13.2 V
I
DD
0.002 μA typ All switches open
1 μA max
220 μA typ S8/S4A closed, V
L
= 5.5 V
380 μA max
270 μA typ S8/S4A closed, V
L
= 2.7 V
440 μA max
I
L
Inactive
6.3 μA typ Digital inputs = 0 V or V
L
8.0 μA max
Inactive, SCLK = 1 MHz 14 μA typ
CS
E
= V
L
and SDI = 0 V or V
L
,
V
L
= 5 V
7 μA typ
CS
E
= V
L
and SDI = 0 V or V
L
,
V
L
= 3 V
SCLK = 50 MHz 390 μA typ
CS
E
= V
L
and SDI = 0 V or V
L
,
V
L
= 5 V
210 μA typ
CS
E
= V
L
and SDI = 0 V or V
L
,
V
L
= 3 V
Inactive, SDI = 1 MHz 15 μA typ
CS
E
and SCLK = 0 V or V
L
, V
L
= 5 V
7.5 μA typ
CS
E
and SCLK = 0 V or V
L
, V
L
= 3 V
SDI = 25 MHz 230 μA typ
CS
E
and SCLK = 0 V or V
L
, V
L
= 5 V
120 μA typ
CS
E
and SCLK = 0 V or V
L
, V
L
= 3 V
Active at 50 MHz 1.8 mA typ
Digital inputs toggle between
0 V and V
L
, V
L
= 5.5 V
2.1 mA max
0.7 mA typ
Digital inputs toggle between
0 V and V
L
, V
L
= 2.7 V
1.0 mA max
V
DD
5 V min GND = 0 V, V
SS
= 0 V
20 V max GND = 0 V, V
SS
= 0 V
1
Guaranteed by design; not subject to production test.
CONTINUOUS CURRENT PER CHANNEL, Sx OR Dx
Table 4. ADGS1408, One Channel On
Parameter 25°C 85°C 125°C Unit
CONTINUOUS CURRENT, Sx OR D
1
V
DD
= 15 V, V
SS
= −15 V (θ
JA
= 58.4°C/W) 304.9 133.6 48.9 mA max
V
DD
= 12 V, V
SS
= 0 V (θ
JA
= 58.4°C/W) 259.7 122.7 48 mA max
V
DD
= 5 V, V
SS
= −5 V (θ
JA
= 58.4°C/W) 247.2 119.3 47.6 mA max
1
Sx refers to the S1 to S8 pins.
Table 5. ADGS1409, Two Channels On
Parameter 25°C 85°C 125°C Unit
CONTINUOUS CURRENT, Sx OR Dx
1
V
DD
= 15 V, V
SS
= −15 V (θ
JA
= 58.4°C/W) 229.6 114.3 47.2 mA max
V
DD
= 12 V, V
SS
= 0 V (θ
JA
= 58.4°C/W) 194.7 103 45.7 mA max
V
DD
= 5 V, V
SS
= −5 V (θ
JA
= 58.4°C/W 185.2 99.6 45.2 mA max
1
Sx refers to the S1A to S4A and S1B to S4B pins, and Dx refers to the DA and DB pins.