ADuM5000W Data Sheet
Rev. A | Page 4 of 15
ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY
4.5 V ≤ V
DD1
≤ 5.5 V, V
SEL
= GND
ISO
, each voltage is relative to its respective ground. All minimum/maximum specifications apply over
the entire recommended operating range, unless otherwise noted. All typical specifications are at T
A
= 25°C, V
DD1
= 5.0 V, V
ISO
= 3.3 V,
and V
SEL
= GND
ISO
.
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions
DC-TO-DC CONVERTER POWER SUPPLY
Setpoint V
ISO
3.0 3.3 3.6 V I
ISO
= 0 mA
Line Regulation V
ISO(LINE)
1 mV/V I
ISO
= 50 mA, V
DD1
= 4.5 V to 5.5 V
Load Regulation V
ISO(LOAD)
1 5 % I
ISO
= 10 mA to 100 mA
Output Ripple V
ISO(RIP)
50 mV p-p 20 MHz bandwidth, C
BO
= 0.1 μF||10 μF,
I
ISO
= 90 mA
Output Noise V
ISO(N)
130 mV p-p C
BO
= 0.1 μF||10 μF, I
ISO
= 90 mA
Switching Frequency f
OSC
180 MHz
PWM Frequency
f
PWM
kHz
I
DD1
Supply Current, Full V
ISO
Load I
DD1(MAX)
250 mA I
ISO
= 100 mA
Maximum Output Supply Current I
ISO(MAX)
100 mA V
ISO
> 3.0 V
Efficiency at Maximum Output
Supply Current
28 % I
ISO
= 100 mA
I
DD1
Supply Current, No V
ISO
Load I
DD1(Q)
3 12 mA I
ISO
= 0 mA
Undervoltage Lockout, V
DD1
and V
ISO
Supply
Positive Going Threshold V
UV+
2.7 V
Negative Going Threshold V
UV−
2.4 V
Hysteresis V
UVH
0.3 V
Data Sheet ADuM5000W
Rev. A | Page 5 of 15
PACKAGE CHARACTERISTICS
Table 5.
Parameter Symbol Min Typ Max Unit Test Conditions
RESISTANCE AND CAPACITANCE
Resistance (Input-to-Output)
1
R
I-O
10
12
Capacitance (Input-to-Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Ambient Thermal Resistance θ
JA
45 °C/W Thermocouple is located at the center of
the package underside; test conducted
on a 4-layer board with thin traces
3
THERMAL SHUTDOWN
Thermal Shutdown Threshold TS
SD
150 °C T
J
rising
Thermal Shutdown Hysteresis TS
SD-HYS
20 °C
1
This device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
3
Refer to the Power Considerations section for thermal model definitions.
REGULATORY INFORMATION
The ADuM5000W is approved by the organizations listed in Table 6. Refer to Table 11 and the Insulation Lifetime section for more
information about recommended maximum working voltages for specific cross isolation waveforms and insulation levels.
Table 6.
UL CSA VDE (Pending)
Recognized under 1577 component
recognition program
1
Approved under CSA Component Acceptance
Notice #5A
Certified according to IEC 60747-5-2 (VDE 0884,
Part 2):2003-01
2
Single protection, 2500 V rms isolation
voltage
Testing was conducted per CSA 60950-1-07
and IEC 60950-1, 2nd Edition at 2.5 kV rated
voltage
Basic insulation at 400 V rms (566 V peak)
working voltage
Reinforced insulation at 250 V rms (353 V peak)
working voltage
Basic insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM5000W is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec (current leakage detection limit = 5 µA).
2
In accordance with IEC 60747-5-2 (VDE 0884, Part 2):2003-01, each ADuM5000W is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial
discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884, Part 2):2003-01.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 7.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.0 mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 7.6 mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Distance (Internal Clearance) 0.017
min
mm Distance through the insulation
Tracking Resistance (Comparative Tracking Index)
CTI
>175
V
DIN IEC 112/VDE 0303 Part 1
Isolation Group
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
ADuM5000W Data Sheet
Rev. A | Page 6 of 15
IEC 60747-5-2 (VDE 0884, PART 2):2003-01 INSULATION CHARACTERISTICS
This power module is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured
by protective circuits. The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884, Part 2):2003-01 approval.
Table 8.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input-to-Output Test Voltage, Method b1
V
IORM
× 1.875 = V
pd(m)
, 100% production test, t
ini
= t
m
= 1
sec, partial discharge < 5 pC
V
pd(m)
1050
V peak
Input-to-Output Test Voltage, Method a V
IORM
× 1.5 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec, partial
discharge < 5 pC
V
pd(m)
After Environmental Tests Subgroup 1 896 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec, partial
discharge < 5 pC
V
pd(m)
672 V peak
Highest Allowable Overvoltage V
IOTM
4000 V peak
Surge Isolation Voltage V
PEAK
= 10 kV, 1.2 µs rise time, 50 µs, 50% fall time V
IOSM
4000 V peak
Safety-Limiting Values Maximum value allowed in the event of a failure
(see
Figure 2)
Maximum Junction Temperature T
S
150 °C
Total Power Dissipation @ 25°C P
S
2.78 W
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Thermal Derating Curve
0
0.5
1.0
1.5
2.0
2.5
3.0
0 50 100 150 200
AMBIENT TEMPERATUREC)
SAFE LIMITING POWER (W)
10971-002
Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Values on Case Temperature, per DIN EN 60747-5-2
RECOMMENDED OPERATING CONDITIONS
Table 9.
Parameter Symbol Min Max Unit Comments
TEMPERATURE
1
Operating Temperature T
A
−40 +105 °C
SUPPLY VOLTAGES
2
Each voltage is relative to its respective ground
V
DD1
at V
SEL
= 0 V V
DD1
2.7 5.5 V
V
DD1
at V
SEL
= 5 V V
DD1
4.5 5.5 V
1
Operation at 105°C requires reduction of the maximum load current as specified in Table 10.
2
Each voltage is relative to its respective ground.

ADUM5000WARWZ

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
DC DC CONVERTER 5V 3.3V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet