PDUMH20ATNET

Management Interface
The management interface for this PDU model is transitioning to a new technology platform. The new
interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place of the
round ENVIROSENSE port. For managing the units containing the round port, Tripp Lite recommends
using the PowerAlert Console Launcher rather than a web browser. This application enables local access
of the PDU using a self-contained, compatible Java Runtime Environment version. The Console Launcher
can be downloaded for free; click the above link or go to the Management Solutions / Utilities page. Units
with the new interface work will with most current web browsers.
1.9kW Single-Phase ATS / Switched PDU with LX
Platform Interface, 120V Outlets (16 5-15/20R), 2
L5-20P / 5-20P 12ft 120V Inputs, 1U Rack-Mount,
TAA
MODEL NUMBER: PDUMH20ATNET
Description
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded
network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power
sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input
cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the
secondary power source until the primary input is restored and stable. Built-in LX Platform network
management interface card. The Java-free LX Platform HTML5-based network interface enables full
remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or
SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.
Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring
capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet,
SSH, FTP, DHCP and NTP. Switched PDU features include individually controllable output receptacles
and built-in network interface. Super-fast switchover between primary and secondary power sources
occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources,
regardless of phase angle, to support a variety of advanced redundant power networking applications.
Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant
UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the
primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite
SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS
configurations utilizing separate mains circuits, backup generators and even separate utility power grid
feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input
sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary
source. Front input LED's display primary or secondary power availability.
Features
Highlights
1.9kW 120V ATS / Switched
PDU, Single phase 20A 120V
Enables redundant A/B power
option for single-corded network
devices
Separate primary & secondary
inputs connect to any two
compatible power sources
1U horizontal rackmount; 2 L5-
20P / 5-20P inputs; 16 5-15/20R
outlets
Switched outlets, Built-in LX
Platform network interface; Two
digit visual current meter
Temperature, humidity and
contact closure monitoring
options
TAA Compliant
Package Includes
ATS / Switched PDU with
attached L5-20P input power
cord
Detachable C19 to NEMA L5-
20P 12 ft/3.6m secondary input
cord
Two NEMA L5-20R to NEMA 5-
20P plug adapters
Installable 1U mounting
brackets
User manual with warranty
information
1 / 4
Specifications
20A 120V Power Distribution Unit (PDU) with LX Platform network interface, Auto-Transfer Switch
(ATS) and Switched outlets (Agency de-rated to 16A)
Provides a redundant A/B power option for non-redundant networking equipment with a single input
power cord
Switched PDU features enable programmable or real-time power control of individual outlets via built-in
network interface
Digital display continuously reports total output power consumption in amps
16 switched NEMA 5-15/20R outlets
1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth
Set of two 12 ft. / 3.6m NEMA L5-20P input cables with set of two 5-20P adapters support connection to
separate PRIMARY and SECONDARY inputs
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails
or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable
until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS
and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-
UPS environment, the primary input cable must be supported by an online UPS with zero transfer time
similar to Tripp Lite SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate
out of phase utility power grid feeds are fully supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the
secondary source when unavailable or of lower quality than the primary source
Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds
LX Platform interface allows full remote access for power monitoring with email notifications via secure
web browser, SNMP, telnet or SSH DHCP/Manual configuration support
10/100 Mbps auto-sensing
Real-time clock backup maintains the time of day and date even if the PDU is unpowered
Alert notifications via email or SNMP traps offer immediate event notification
Firmware upgrade ability supports future product enhancements
Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring
capabilities
Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first
energized
Front panel LEDs confirm power availability on both input lines
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
2 / 4
OVERVIEW
UPC Code 037332136411
PDU Type Auto-Transfer Switch; Switched
OUTPUT
Output Capacity Details 2.03kW (127V), 1.92kW (120V), 1.6kW (100V) / 20A total capacity (Agency de-rated to 16A); 16A max per outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (16) 5-15/20R
Output Nominal Voltage 100; 120; 127
Overload Protection n/a
Customized Load Management
Receptacles
16 individually switched output receptacles
INPUT
PDU Input Voltage 100; 120; 127
Recommended Electrical Service 20A 120V
Maximum Input Amps 20.0
Maximum Input Amps Details Agency de-rated to 16A continuous
PDU Plug Type (2) NEMA 5-20P; (2) NEMA L5-20P
Input Cord Details Set of two L5-20P cordsets with two 5-20P adapters enable connection to separate PRIMARY and SECONDARY
power sources
Input Cord Length (ft.) 12
Input Cord Length (m) 3.66
Input Phase Single-Phase
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports total PDU output current in amps
Front Panel LEDs 16 front panel LEDs display power on / off status for each outlet, plus 2 LEDs for power status on each input line
cord; Digital current meter display shows the amount of power consumption in amps for entire output of PDU.
Switches n/a
PHYSICAL
Minimum Required Rack Depth
(inches)
19.5
Minimum Required Rack Depth (cm) 49.53
Shipping Dimensions (hwd / in.) 5.40 x 20.70 x 22.90
Shipping Dimensions (hwd / cm) 13.72 x 52.58 x 58.17
Shipping Weight (lbs.) 20.00
3 / 4

PDUMH20ATNET

Mfr. #:
Manufacturer:
Tripp Lite
Description:
Power Outlet Strips Metered PDU w/ATS 120V 16 outlets RM
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet