1
02-2014, Rev. 0214
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
Potter & Brumfield
T90 Series, 30A PCB Relay
Coil Data
Coil voltage range 5 to 110VDC
Max. coil power 1.0W
Max. coil temperature 155°C
Coil insulation system according UL Class F
Coil versions, DC coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% wW
5 5 3.75 0.5 27 900
6 6 4.5 0.6 40 900
9 9 6.75 0.9 97 900
12 12 9 1.2 155 900
18 18 13.5 1.8 380 900
24 24 18 2.4 660 900
48 48 36 4.8 2560 900
110 110 82.5 11 13450 900
All figures are given for coil without preenergization, at ambient temperature +23°C.
Ambient temperature vs. coil voltage – 1W coil
Data graphed above are average values and should be verified in application. Tests were
conducted within a 2’ (.6m) cube (still air); at nominal coil power @ 25°C; with normally
open contact loaded; and with 4’ (1.22m) long, #10AWG load wires. P.C. board relays were
mounted to a 30A, single side P.C. board. Coil rise test conducted with a 30A PC board
to maintain 20°C max. rise at 30°C. The relay connections and wiring must be designed
with an adequate cross section to ensure proper current flow and heat dissipation. After
cleaning process knock-off nib should be removed for optimum life of wash-tight relays.
n
30A, 1 form A (NO); 20A, 1 form C (CO)
n
Available as open frame or sealed construction
n
Meets UL 508 and 873 Spacing - 3.18 through air, 6.36 over surface
n
UL class F insulation system standard
Typical applications
HVAC, Appliances, Industrial Controls.
Approvals
UL E22575; CSA LR15734
Technical data of approved types on request.
Contact Data
Contact arrangement
1 form A (NO), 1 form B (NC), 1 form C (CO)
Rated voltage 277VAC
Max. switching voltage 277VAC
Rated current 30A
Limiting continuous current 30A
Limiting making current 30A
Limiting breaking current 30A
Contact material AgCdO
Min. recommended contact load 1A, 5VDC or 12VAC
Initial contact resistance 75 mΩ at 1A at 5VDC or 12VAC
Frequency of operation, with load 360hr
Operate/release time max., including bounce 15/15ms
Contact ratings
Type Load Cycles
Typical
AgCdO, open style relay
NO 30A, 240VAC, general purpose 100x10
3
NO 20A, 240VAC, resistive heater 100x10
3
CO 20A/10A, 240VAC, general purpose 100x10
3
CO 20A/10A, 28VDC, resistive 100x10
3
UL 508/873
AgCdO
NO 30A, 240VAC, general purpose 100x10
3
NC 15A, 240VAC, general purpose 100x10
3
CO 20A/10A, 240VAC, general purpose 100x10
3
NO 20A, 240VAC, resistive 100x10
3
NC 15A, 240VAC, resistive 100x10
3
CO 20A/10A, 240VAC, resistive 100x10
3
NO 80LRA/30FLA, 240VAC 30x10
3
NC 30LRA/10FLA, 240VAC 30x10
3
CO 53.6LRA/20FLA / 20LRA/6.7FLA, 240VAC 100x10
3
NO 98LRA/22FLA, 120VAC 100x10
3
NO 2HP, 240VAC 1x10
3
NC 1/2HP, 240VAC 1x10
3
NO 1HP, 120VAC 1x10
3
NC 1/4HP, 120VAC 1x10
3
NO 6A, 277VAC, ballast 100x10
3
NC 3A, 277VAC, ballast 6x10
3
NO TV5, 240VAC, tungsten 6x10
3
NC TV3, 240VAC, tungsten 6x10
3
NO 20A, 28VDC, resistive 100x10
3
NC 10A, 28VDC, resistive 100x10
3
All ratings at 25°C (unless otherwise noted) with relay properly vented. Remove vent nib
from enclosed relays after soldering and cleaning for optimum life.
Mechanical endurance 10x10
6
ops.
120
110
100
90
80
70
60
50
40
30
20
50 75 100 125 150 175 200
30A Load
25A Load
20A Load
15A Load
10A Load
0A Load
150
140
130
120
110
100
90
80
70
60
50
40
30
20
50 75 100 125 150 175 200
Wash Tight Relay, Vented
0A Load
10A Load
30A Load
25A Load
20A Load
15A Load
Open Style Relay, No Dust Cover
Applied Continuous Coil Voltage (% of Rated Voltage)
Coil Temp. Rise Above Ambient (°C)
Applied Continuous Coil Voltage (% of Rated Voltage)
Coil Temp. Rise Above Ambient (°C)
General Purpose
High Power PCB Relays