MAX2014EUA+T

General Description
The MAX2014 complete multistage logarithmic amplifier is
designed to accurately convert radio-frequency (RF) sig-
nal power in the 50MHz to 1000MHz frequency range to
an equivalent DC voltage. The outstanding dynamic range
and precision over temperature of this log amplifier make it
particularly useful for a variety of base-station and other
wireless applications, including automatic gain control
(AGC), transmitter power measurements, and received-
signal-strength indication (RSSI) for terminal devices.
The MAX2014 can also be operated in a controller
mode where it measures, compares, and controls the
output power of a variable-gain amplifier as part of a
fully integrated AGC loop.
This logarithmic amplifier provides much wider mea-
surement range and superior accuracy compared to
controllers based on diode detectors, while achieving
excellent temperature stability over the full -40°C to
+85°C operating range.
Applications
AGC Measurement and Control
RF Transmitter Power Measurement
RSSI Measurements
Cellular Base-Station, WLAN, Microwave Link,
Radar, and other Military Applications
Optical Networks
Features
Complete RF Detector/Controller
50MHz to 1000MHz Frequency Range
Exceptional Accuracy Over Temperature
High Dynamic Range
2.7V to 5.25V Supply Voltage Range*
Scaling Stable Over Supply and Temperature
Variations
Controller Mode with Error Output
Shutdown Mode with Typically 1µA of Supply
Current
Available in 8-Pin TDFN and 8-pin µMAX
®
Package
MAX2014
50MHz to 1000MHz, 75dB Logarithmic
Detector/Controller
________________________________________________________________
Maxim Integrated Products
1
MAX2014
7dB
Σ
50Ω
20kΩ
SET
OUT
8
7
2
INHI
INLO
3
6
1, 4
PWDN
5
20kΩ
Σ
7dB
Σ
7dB
V
CC
GND
POWER DETECTORS
OFFSET AND COMMON-
MODE AMP
Functional Diagram
19-0583; Rev 1; 2/12
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
Pin Configuration appears at end of data sheet.
*
See the Power-Supply Connections section.
Ordering Information appears at end of data sheet.
µMAX is a registered trademark of Maxim Integrated Products, Inc.
MAX2014
50MHz to 1000MHz, 75dB Logarithmic
Detector/Controller
2
ABSOLUTE MAXIMUM RATINGS
DC ELECTRICAL CHARACTERISTICS
(
Typical Application Circuit
(Figure 1), V
S
= +3.3V, f
RF
= 50MHz to 1000MHz, R1 = 0Ω, R4 = 0Ω, R
L
= 10kΩ, T
A
= -40°C to +85°C,
unless otherwise noted. Typical values are at T
A
= +25°C, unless otherwise noted.) (Note 2)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
V
CC
(Pins 1, 4) to GND........................................-0.3V to +5.25V
SET, PWDN to GND....................................-0.3V to (V
CC
+ 0.3V)
Input Power Differential INHI, INLO................................+23dBm
Input Power Single Ended (INHI or INLO grounded).....+19dBm
Continuous Power Dissipation (T
A
= +70°C)
TDFN (derate 18.5mW/°C above +70°C)....................1480mW
µMAX (derate 4.5mW/°C above +70°C) .......................362mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
POWER SUPPLY
R4 = 75Ω ±1%, PWDN must be
connected to GND
4.75 5.25
Supply Voltage V
S
R4 = 0Ω 2.7 3.6
V
T
A
= +25°C, V
S
= 5.25V,
R4 = 75Ω
17.3
Supply Current I
CC
T
A
= +25°C 17.3 20.5
mA
Supply Current Variation with Temp I
CC
T
A
= -40°C to +85°C 0.05 mA/°C
Shutdown Current I
CC
V
PWDN
= V
CC
A
CONTROLLER REFERENCE (SET)
SET Input Voltage Range 0.5 to 1.8 V
SET Input Impedance 40 kΩ
DETECTOR OUTPUT (OUT)
Source Current 4mA
Sink Current 450 µA
Minimum Output Voltage V
OUT
(
MIN
)
0.5 V
Maximum Output Voltage V
OUT
(
MAX
)
1.8 V
TDFN:
Junction-to-Ambient Thermal Resistance (θ
JA
) ............54°C/W
Junction-to-Case Thermal Resistance (θ
JC
) ...................8°C/W
µMAX:
Junction-to-Ambient Thermal Resistance (θ
JA
) ..........221°C/W
Junction-to-Case Thermal Resistance (θ
JC
) .................42°C/W
Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7. For detailed
information on package thermal considerations, refer to www.maxim-ic.com/thermal-tutorial
.
PACKAGE THERMAL CHARACTERISTICS (Note 1)
MAX2014
50MHz to 1000MHz, 75dB Logarithmic
Detector/Controller
3
AC ELECTRICAL CHARACTERISTICS
(
Typical Application Circuit
(Figure 1), V
S
= +3.3V, f
RF
= 50MHz to 1000MHz, R1 = 0Ω, R4 = 0Ω, R
L
= 10kΩ, T
A
= -40°C to +85°C,
unless otherwise noted. Typical values are at T
A
= +25°C, unless otherwise noted.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
RF Input Frequency Range f
RF
50 to 1000 MHz
Return Loss S
11
-15 dB
Large-Signal Response Time
P
IN
= no signal to 0dBm,
±0.5dB settling accuracy
150 ns
RSSI MODE—50MHz
RF Input Power Range (Note 3) -65 to +5 dBm
±3dB Dynamic Range T
A
= -40°C to +85°C (Note 4) 70 dB
Range Center -30 dBm
Temp Sensitivity when T
A
> +25°C
T
A
= +25°C to +85°C,
P
IN
= -25dBm
+0.0083 dB/°C
Temp Sensitivity when T
A
< +25°C
T
A
= -40°C to +25°C,
P
IN
= -25dBm
-0.0154 dB/°C
Slope (Note 5) 19 mV/dB
Typical Slope Variation T
A
= -40°C to +85°C -4 µV/°C
Intercept (Note 6) -100 dBm
Typical Intercept Variation T
A
= -40°C to +85°C 0.03 dBm/°C
RSSI MODE—100MHz
RF Input Power Range (Note 3) -65 to +5 dBm
±3dB Dynamic Range T
A
= -40°C to +85°C (Note 4) 70 dB
Range Center -30 dBm
Temp Sensitivity when T
A
> +25°C
T
A
= +25°C to +85°C,
P
IN
= -25dBm
+0.0083 dB/°C
Temp Sensitivity when T
A
< +25°C
T
A
= -40°C to +25°C,
P
IN
= -25dBm
-0.0154 dB/°C
Slope (Note 5) 19 mV/dB
Typical Slope Variation T
A
= -40°C to +85°C -4 µV/°C
Intercept (Note 6) -100 dBm
Typical Intercept Variation T
A
= -40°C to +85°C 0.03 dBm/°C
RSSI MODE—900MHz
RF Input Power Range (Note 3) -65 to +5 dBm
±3dB Dynamic Range T
A
= -40°C to +85°C (Note 4) 70 dB
Range Center -30 dBm
Temp Sensitivity when T
A
> +25°C
T
A
= +25°C to +85°C,
P
IN
= -25dBm
±0.0083 dB/°C

MAX2014EUA+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
RF Detector 50-1000MHz 75dB Log Detector/Ctlr
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet