6
All Avago data sheets report the creepage and clearance
inherent to the optocoupler component itself. These
dimensions are needed as a starting point for the
equipment designer when determining the circuit insula-
tion requirements. However, once mounted on a printed
circuit board, minimum creepage and clearance require-
ments must be met as specied for individual equipment
standards. For creepage, the shortest distance path along
the surface of a printed circuit board between the solder
llets of the input and output leads must be considered.
There are recommended techniques such as grooves
and ribs, which may be used on a printed circuit board
to achieve desired creepage and clearances. Creepage
and clearance distances will also change depending
on factors such as pollution degree and insulation
level.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (Option 060)
Description Symbol
Characteristic
UnitHCPL-7723 HCPL-0723
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 V
rms
I – IV I – IV
for rated mains voltage ≤ 300 V
rms
I – III I – III
for rated mains voltage ≤ 600 V
rms
I – IV I – III
Climatic Classication 55/85/21 55/85/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
630 567 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
=1 sec,
Partial discharge < 5 pC
V
PR
1181 1063 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test, t
m
=10 sec, Partial discharge < 5 pC V
PR
1008 907 V
peak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 60 sec) V
IOTM
8000 6000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature T
S
175 150
°C
Input Current I
S, INPUT
230 150 mA
Output Power P
S, OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥ 10
9
≥ 10
9
Ω
*Refer to the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section IEC/EN/
DIN EN 60747-5-5, for a detailed description of Method a and Method b partial discharge test proles.