9
Package Characteristics
All Typical Specications are at T
A
= 25°C.
Parameter Symbol Min. Typ. Max. Units Test Conditions
Input-Output Momentary –7723 V
ISO
3750 V rms RH ≤ 50%, t = 1 min,
Withstand Voltage
[7,8,9]
Option 020 5000 T
A
= 25°C
–0723 3750
Input-Output Resistance
[7]
R
I-O
10
12
Ω V
I-O
= 500 V dc
Input-Output Capacitance C
I-O
0.6 pF f = 1 MHz
Input Capacitance
[10]
C
I
3.0 pF
Input IC Junction-to-Case –7723 θ
jci
145 °C/W Thermocouple located at
Thermal Resistance –0723 160 center underside of package
Output IC Junction-to-Case –7723 θ
jco
145 °C/W
Thermal Resistance –0723 135
Package Power Dissipation P
PD
150 mW
Notes:
1. Absolute Maximum ambient operating temperature means the device will not be damaged if operated under these conditions. It does not
guarantee functionality.
2. The LED is ON when V
I
is low and OFF when V
I
is high.
3. t
PHL
propagation delay is measured from the 50% level on the falling edge of the VI signal to the 50% level of the falling edge of the V
O
sig-
nal. t
PLH
propagation delay is measured from the 50% level on the rising edge of the VI signal to the 50% level of the rising edge of the V
O
signal.
4. PWD is dened as |t
PHL
- t
PLH
|. %PWD (percent pulse width distortion) is equal to the PWD divided by pulse width.
5. t
PSK
is equal to the magnitude of the worst case dierence in t
PHL
and/or t
PLH
that will be seen between units at any given temperature
within the recommended operating conditions.
6. CMH is the maximum common mode voltage slew rate that can be sustained while maintaining V
O
> 0.8 V
DD2
. CML is the maximum com-
mon mode voltage slew rate that can be sustained while maintaining V
O
< 0.8 V. The common mode voltage slew rates apply to both rising
and falling common mode voltage edges.
7. Device considered a two-terminal device: pins 1, 2, 3, and 4 shorted together and pins 5, 6, 7, and 8 shorted together.
8. In accordance with UL1577, each HCPL-0723 is proof tested by applying an insulation test voltage ≥ 4500 Vrms for 1 second (leakage detec-
tion current limit, I
I-O
≤ 5 µA). Each HCPL-7723 is proof tested by applying an insulation test voltage ≥ 4500 Vrms for 1 second (leakage detec-
tion current limit. I
I-O
≤ 5 µA.)
9. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to your equipment level safety specication or Avago Application Note 1074 entitled
“Optocoupler Input-Output Endurance Voltage.”
10. C
I
is the capacitance measured at pin 2 (V
I
).