I
NTEGRATED
C
IRCUITS
D
IVISION
LBA710
www.ixysic.com
5
R03
LED Current (mA)
0.20 0.21 0.22 0.23 0.24 0.25 0.26
Device Count (N)
0
5
10
15
20
25
Form-B
Typical LED Current to Operate
(N=50, I
L
=1A)
Turn-On Time (ms)
0.54 0.57 0.60 0.63 0.66 0.69 0.72
Device Count (N)
0
5
10
15
20
25
Form-B
Typical Turn-On Time
(N=50, I
F
=5mA)
Turn-Off Time (ms)
1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9
Device Count (N)
0
5
10
15
20
Form-B
Typical Turn-Off Time
(N=50, I
F
=5mA)
LED Forward Voltage (V)
1.220 1.225 1.230 1.235 1.240 1.245 1.250
Device Count (N)
0
5
10
15
20
25
30
Form-B
Typical LED Forward Voltage Drop
(N=50)
On-Resistance (:)
0.381 0.384 0.387 0.390 0.393 0.396 0.399
Device Count (N)
0
5
10
15
20
Form-B
Typical On-Resistance Distribution
(N=50, I
F
=0mA, I
L
=1A)
Blocking Voltage (V
P
)
69 71 73 75 77 79 81
Device Count (N)
0
5
10
15
20
25
Form-B
Typical Blocking Voltage Distribution
(N=50, I
F
=2mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
LED Current (mA)
0.12
0.16
0.20
0.24
0.28
0.32
Form-B
Typical I
F
for Switch Operation
vs. Temperature
(I
L
=100mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Turn-On Time (ms)
0.4
0.5
0.6
0.7
0.8
0.9
Form-B
Typical Turn-On Time
vs. Temperature
(I
F
=5mA, I
L
=100mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Turn-Off Time (ms)
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
Form-B
Typical Turn-Off Time
vs. Temperature
(I
F
=5mA, I
L
=100mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
LED Forward Voltage (V)
1.0
1.1
1.2
1.3
1.4
1.5
1.6
Form-B
Typical LED Forward Voltage Drop
vs. Temperature
I
F
=50mA
I
F
=20mA
I
F
=10mA
I
F
=5mA
I
F
=2mA
LED Forward Current (mA)
0 1020304050
Turn-On Time (ms)
0.620
0.622
0.624
0.626
0.628
0.630
0.632
0.634
0.636
0.638
0.640
Form-B
Typical Turn-On Time
vs. LED Forward Current
(I
L
=100mA)
LED Forward Current (mA)
0 1020304050
Turn-Off Time (ms)
0
1
2
3
4
5
6
7
8
Form-B
Typical Turn-Off Time
vs. LED Forward Current
(I
L
=100mA)
Form-B PERFORMANCE DATA*
*Unless otherwise noted, data presented in these graphs is typical of device operation at 25ºC.
For guaranteed parameters not indicated in the written specifi cations, please contact our Application Department.