Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER. AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 2
Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2010-2013 Tyco Electronics Corporation,. All rights reserved.
TABLE I. CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
DIAMETER OF
STRANDED
CONDUCTOR
(in.)
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft)
DIAMETER
(in.)
MAXIMUM
WEIGHT
(lbs/1000 ft.)
MINIMUM MAXIMUM
55/0112-30-* 30 7 x 38 .011 .012 100.7 .024 ± .002 .66
55/0112-28-* 28 7 x 36 .014 .015 63.8 .027 ± .002 .91
55/0112-26-* 26 19 x 38 .018 .019 38.4 .032 ± .002 1.4
55/0112-24-* 24 19 x 36 .023 .025 24.3 .037 ± .002 2.0
55/0112-22-* 22 19 x 34 .029 .030 15.1 .043 ± .002 2.8
55/0112-20-* 20 19 x 32 .037 .039 9.19 .050 ± .002 4.3
55/0112-18-* 18 19 x 30 .046 .048 5.79 .060 ± .002 6.5
55/0112-16-* 16 19 x 29 .052 .054 4.52 .068 ± .002 8.3
55/0112-14-* 14 19 x 27 .065 .068 2.88 .085 ± .003 13.0
55/0112-12-* 12 37 x 28 .084 .087 1.90 .103 ± .003 19.7
55/0112-10-* 10 37 x 26 .106 .112 1.19 .128 ± .006 32.3
55/0112-8-* 8 133 x 29 .158 .169 .658 .188 ± .008 60.5
TABLE II. PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (± 3%)
WEIGHT
(lb) (± 3%)
CROSSLINKED VERIFICATION CROSSLINKED VERIFICATION
55/0112-30-* .250 .125
55/0112-28-* .250 .125
55/0112-26-* .375 .125
55/0112-24-* .375 .250
55/0112-22-* .500 .375
55/0112-20-* .500 .500
55/0112-18-* .500 .500
55/0112-16-* .750 .750
55/0112-14-* 1.00 1.00
55/0112-12-* 1.50 1.50
55/0112-10-* 2.00 1.50
55/0112-8-* 3.00 4.00
CONDUCTOR - SILVER-COATED COPPER
INSULATION - LOW OUTGASSING,
RADIATION-CROSSLINKED,
MODIFIED ETFE
SPECIFICATION CONTROL DRAWING
55/0112
WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED,
LIGHTWEIGHT, GENERAL PURPOSE, OUTER SPACE, 600 VOLT
4-30-13 H
This specication sheet forms a part of the latest issue of Raychem Specication 55/.
TITLE
Date Revision