Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MI-J00 DC-DC Converters 10 to 50 Watts Rev. 1.1 Page 1 of 6
Set your site on VICOR at vicorpower.com
Input Voltage
Operating Storage
I = 40 to +100 I = 55 to +125
M = 55 to +100 M = 65 to +125
Features
Inputs:
28 Vdc per MIL-STD-704D/E/F
155 Vdc per MIL-STD-1399A
270 Vdc per MIL-STD-704D/E/F
Single output: 2 – 48 Vdc
Up to 23 W/in
3
MIL-STD-810 environments
Up to 90% efficiency
Remote sense
Current limit
ZCS power architecture
Low noise FM control
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7 mm)
Product Highlights
The MI-J00 family of DC-DC converters is
designed for applications utilizing distributed
power architectures. Based on Vicor’s VI-200 /
VI-J00 family of zero-current switching,
component-level DC-DC converters, the MI-J00
family offers exceptional performance in terms of
power density, efficiency, noise, ease of use, and
reliability.
The MI-J00 family meets all steady-state,
transient andunder/overvoltage requirements of
MIL-STD-704D/E/F for both 28 Vdc input
(MI-J2X) and 270 Vdc input (MI-J6X), and the
worst case envelope of MIL-STD-1399A for
155 Vdc input (MI-J5X).
The output voltage can be externally trimmed or
programmed from 50% to 110% of nominal
output. Current limiting, remote sense, and an
inhibit pin all combine to offer a high degree of
protection, versatility, and reliability for power
systems.
Fully encapsulated in Vicor’s industry standard
package, the MI-J00 family meets MIL-STD-810
environmental testing requirements for humidity,
fungus, salt-fog, explosive atmosphere,
acceleration, vibration, and shock.
Packaging Options
Standard: Slotted baseplate
SlimMod: Flangeless baseplate, option suffix: - S
Example: MI - JXX - XX - S
FinMod: Finned heat sink, option suffix:
- F1, -F2, -F3 and - F4
Examples:
MI - JXX - XX -F1, 0.25" fins, longitudinal
MI - JXX - XX -F2, 0.50" fins, longitudinal
MI - JXX - XX -F3, 0.25" fins, transverse
MI - JXX - XX -F4, 0.50" fins, transverse
≥ 5 V <5 V
A = 10 W A =—
Z = 25 W Z =5 A
Y = 50 W Y = 10 A
Z = 2.0 V
Y = 3.3 V
0 = 5.0 V
X = 5.2 V
W = 5.5 V
V = 5.8 V
T = 6.5 V
R = 7.5 V
M = 10 V
1 = 12 V
P = 13.8 V
2 = 15 V
N = 18.5 V
3 = 24 V
L = 28 V
J = 36 V
K = 40 V
4 = 48 V
MI-J
Converter Selection Chart
Semi-custom modules available, consult factory.
Product Grade Temperatures (°C)
Output Power/Current Vout
Output Voltage
Nominal Range Transient
[a]
Notes
2 = 28 V 18 50 V
[b]
60 V 28 Vdc input per MIL-STD 704D/E/F
5 = 155 V 100 210 V 230 V 155 Vdc input per MIL-STD-1399A
6 = 270 V 125 400 V
[c]
475 V 270 Vdc input per MIL-STD-704D/E/F
7 = 165 V 100 310 V n/a
Data Sheet
MI-J00
DC-DC Converters
10 to 50 Watts
[a]
Transient voltage for 1 second.
[b]
16 V operation at 75% load.
[c]
These units rated at 75% load from 125 – 150 Vin: MI-J6Z-xY, MI-J6Y-xY, MI-J60-xY
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MI-J00 DC-DC Converters 10 to 50 Watts Rev. 1.1 Page 2 of 6
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Units Test Conditions
Inrush charge 60 x 10
-6
100 x 10
-6
Coulombs Nominal line
Input reflected
10% I
IN Nominal line, full load
ripple current – pp
Input ripple rejection
dB 120 Hz, nominal line
dB 2400 Hz, nominal line
No load power dissipation 1.35 2 Watts
Parameter Min Typ Max Units Test Conditions
Gate out impedance 50 -
Gate in impedance 1000 -
Gate in high threshold 6 Volts Use open collector
Gate in low threshold 0.65 Volts
Gate in low current 6 mA
Parameter Min Typ Max Units Test Conditions
Setpoint accuracy 0.5 1 %VNOM
Load/line regulation
0.05 0.2 %V
NOM LL to HL, 10% to Full Load
0.2 0.5 %VNOM LL to HL, No Load to 10%
Output temperature drift 0.01 0.02 % / °C Over rated temperature
Long term drift 0.02 %/1K hours
Output ripple – pp
100 150 mV
Whichever is greater
1.0 1.5 %VNOM
20 MHz bandwidth
Trim range
[a]
50 110 %VNOM
Total remote
0.5 Volts
sense compensation
Current limit 105 125 %INOM Automatic restart
Short circuit current 105 130 %I
NOM
CONVERTER SPECIFICATIONS
(typical at T
BP
= 25°C, nominal line and 75% load, unless otherwise specified)
30+20 Log
(
Vin
)
Vout
20+20 Log
(
Vin
)
Vout
INPUT SPECIFICATIONS
OUTPUT CHARACTERISTICS
CONTROL PIN SPECIFICATIONS
[a]
10 V, 12 V and 15 V outputs, standard trim range ±10%. Consult factory for wider trim range.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MI-J00 DC-DC Converters 10 to 50 Watts Rev. 1.1 Page 3 of 6
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Units Test Conditions
Efficiency 80 – 90%
Baseplate to sink 0.14 °C/Watt With thermal pads
CONVERTER SPECIFICATIONS (cont.)
Parameter Min Typ Max Units Test Conditions
Input to output 3,000 VRMS Baseplate earthed
Output to baseplate 500 VRMS
Input to baseplate 1,500 VRMS
Input to output capacitance 50 75 pF
Parameter Min Typ Max Units Test Conditions
Altitude - method 500.2 70,000 feet Procedure II
Humidity - method 507.2 88/240 %/hours Procedure I, cycle 1
Acceleration - method 513.3 9 g Procedure II
Vibration - method 514.3 20 g Procedure I, category 6
Shock - method 516.3 40 g Procedure I
DIELECTRIC WITHSTAND CHARACTERISTICS
THERMAL CHARACTERISTICS
ENVIRONMENTAL – MIL-STD-810D
Parameter Min Typ Max Units Test Conditions
25°C Ground Benign: G.B. 3,732 1,000 hours
50°C Naval Sheltered: N.S. 672 1,000 hours
65°C Airborne Inhabited
Cargo: A.I.C.
526 1,000 hours
RELIABILITY - MIL-HDBK-217F (MI-J2L-MY)
Parameter Min Typ Max Units Test Conditions
Weight
3.5 3.7 3.8 Ounces
101 107 109 Grams
MECHANICAL SPECIFICATIONS

MI-J74-MA-S

Mfr. #:
Manufacturer:
Vicor
Description:
Isolated DC/DC Converters VI J00/200 - 165 Vin, 48 Vout, 10 W, M Product Grade
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union