DMC20261NYJ-LY-BCE (CD) No.99-0207 OPTREX CORPORATION Page 10/16
OPTREX
5.Test
No change on display and in operation under the following test condition.
No. Parameter Conditions Notes
1 High Temperature Operating 70
℃±
2
℃
, 96hrs (operation state)
2 Low Temperature Operating -20
℃±
2
℃
, 96hrs (operation state) 3
3 High Temperature Storage 70
℃±
2
℃
, 96hrs 4
4 Low Temperature Storage -20
℃±
2
℃
, 96hrs 3, 4
5 Damp Proof Test 40
℃±
2
℃
, 90
~
95%RH, 96hrs 3, 4
6 Vibration Test Total fixed amplitude : 1.5mm 5
Vibration Frequency : 10
~
55Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7 Shock Test To be measured after dropping from 60cm high on
the concrete surface in packing state.
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.
Temperature : 20
±
5
℃
Humidity : 65
±
5%
Note 2 : Unless otherwise specified, tests will be not conducted under functioning state.
Note 3 : No dew condensation to be observed.
Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity
after removed from the test chamber.
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.
E
A
G
D
C
F
60cm
Concrete Surface
Dropping method corner dropping
E,F,G face : once
B,C,D edge : once
A corner : once
Face dropping
Edge dropping
B