SPECIFICATION CONTROL DRAWING
2 of 2 G
FLHT+0312
Page
Revision
SCD
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
VOLTAGE RATING: 600 volts (rms) at sea level
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
FLAME RATING: VW-1
INSULATION ELONGATION AND TENSILE STRENGTH:
Elongation, 100% (minimum)
Tensile Strength, 5470 lbf/in
2
(minimum)
INSULATION FLAWS:
Spark Test, 6.0 kV (rms)
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS:
AWG 28 - 16: .0055 inch (minimum), .006 inch (minimum average)
AWG 14: .006 inch (minimum), .0065 inch (minimum average)
AWG 12: .0065 inch (minimum), .007 inch (minimum average)
1/ See footer section on page 1
SHRINKAGE: 200°C for 1 hour, 0.125 in. (maximum) per end
THERMAL STABILITY: 232°C for 168 hours,
Elongation, 60% (minimum)
Tensile Strength, 5000 lbf/in
2
(minimum)
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes
PART NUMBER:
The “+” in the part number in the upper right hand corner of pages 1 and 2 shall be replaced with
a letter designator to dene conductor stranding (see part numbers in table).
B = 7 Strands C = 19 Strands D = 37 Strands
The “*” in the part numbers in tables I and II shall be replaced by a color code designator.
1/ Example: AWG 18, 19 strands, white: FLHTC0312-18-9
AWG 18, 19 strands, white with black stripe: FLHTC0312-18-90
TABLE II. PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (mm) (± 3%)
WEIGHT
(lb) (kg) (± 3%)
CROSSLINK VERIFICATION CROSSLINK VERIFICATION
FLHTB0312-28-* .375 (9.53) .125 (.057)
FLHTC0312-26-* .375 (9.53) .125 (.057)
FLHTC0312-24-* .375 (9.53) .500 (.227)
FLHTC0312-22-* .500 (12.7) .750 (.340)
FLHTC0312-20-* .500 (12.7) 1.00 (.454)
FLHTC0312-18-* .500 (12.7) 1.00 (.454)
FLHTC0312-16-* .750 (19.1) 1.50 (.680)
FLHTC0312-14-* 1.00 (25.4) 2.00 (.907)
FLHTD0312-14-* 1.00 (25.4) 2.00 (.907)
FLHTD0312-12-* 1.50 (38.1) 3.00 (1.36)