PD-4
REV.: 2/2017 www.recom-power.com
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP15-AW
Series
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous, automatic recovery
Over Voltage Protection (OVP) Zener Diode Clamp
3.3Vout
5Vout
12Vout
15Vout
3.7 - 5.4V
5.6 - 7.0V
13.5 - 19.6V
16.8-20.5V
Over Load Protection (OLP) % of Iout rated 150% typ.
Isolation Voltage
I/P to O/P
I/P (O/P) to case
1.6kVDC/1 minute
1.0kVDC/1 minute
Isolation Resistance 1GΩ min.
Isolation Capacitance 1000pF max.
Notes:
Note7: This power module is not internally fused. An input line fuse must always be used.
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 5.05 5.10 5.15 5.20 5.25 5.30 5.35 5.4 5.45 5.50 Volts
R
U
= 36.57 16.58 9.92 6.58 4.59 3.25 2.30 1.59 1.03 0.59 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 4.55 4.50 Volts
R
D
= 45.53 20.61 12.31 8.15 5.66 4.00 2.81 1.92 1.23 0.68 kOhms
RP15-xx05SA
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 Volts
R
U
= 367.91 165.95 98.64 64.98 44.78 31.32 21.70 14.49 8.88 4.39 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 10.92 10.8 Volts
R
D
= 460.99 207.95 123.60 81.42 56.12 39.25 27.20 18.16 11.13 5.51 kOhms
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 15.15 15.3 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 Volts
R
U
= 404.18 180.59 106.06 68.80 46.44 31.53 20.88 12.90 6.69 1.72 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 14.85 14.70 14.55 14.40 14.25 14.10 13.95 13.80 13.65 13.50 Volts
R
D
= 499.82 223.41 131.27 85.20 57.56 39.14 25.97 16.10 8.42 2.282 kOhms
RP15-xx12SA
RP15-xx15SA