RP15-2405SAW/P-HC

DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP15-AW
Series
PD-7
REV.: 2/2017www.recom-power.com
Dimension Drawing (mm)
Dimension Drawing (mm) with Heat-sink
Bottom View
Standard
4
4
6
1
1
2
2
Bottom View
CTRL Option
5
6
3
20.32
20.32
25.4
2.54
20.32
5.08
5.08
10.1610.16
2.54
Top View
Ø1.60 +0.15/-0
2.54
25.4
5.6
9.9
Ø 1.0
24.20
24.20
Top View
Heat-sink
25.4
31.4
Ø 1.0
5.6
16.5
9.9
20.32
25.4
2.54
5.85
Pin Connections
Pin # Single
Single
/P or /N
Dual
Dual
/P or /N
1 +Vin +Vin +Vin +Vin
2 -Vin -Vin -Vin -Vin
3 no Pin CTRL no Pin CTRL
4 +Vout +Vout +Vout +Vout
5 no Pin Trim Com Com
6 -Vout -Vout -Vout -Vout
Case Tolerance ±0.5mm
Pin Pitch Tolerance ±0.25mm
XX.X ± 0.5mm
XX.XX ± 0.25mm
PD-8
REV.: 2/2017 www.recom-power.com
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP15-AW
Series
PACKAGING INFORMATION
Parameter Type Value
Packaging Quantity
without Heat-sink
with Heat-sink
Tube
Tray
8pcs.
20pcs.
Storage Temperature Range -55°C to +125°C
Storage Humidity 5% - 95% RH
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.

RP15-2405SAW/P-HC

Mfr. #:
Manufacturer:
RECOM Power
Description:
Isolated DC/DC Converters 15W DC/DC 1.6kV REG 4:1 9-36Vin 5Vout
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: