2308098

https://www.phoenixcontact.com/pi/products/2308098
08/19/2018Page1/4
Universal current transducer-MCR-SL-CUC-600-I-2308098
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Universal current transducer, for measuring DC, AC, and distorted currents, 0 ... 600 A input current, 4 ... 20
mA output
Why buy this product
Variable mounting on DIN rail and mounting plate
Simple connection technology thanks to COMBICON plug-in connection terminal blocks
Compact dimensions also enable distributed use
3-way isolation
Universal current measurement, no shunt required
Key Commercial Data
Packing unit 1 STK
GTIN
GTIN 4046356566988
Technical data
Dimensions
Primary round conductor (diameter) 32 mm
Width 90 mm
Height 33.8 mm
Depth 85 mm
Ambient conditions
Ambient temperature (operation) -40 °C ... 65 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Input data
Number of inputs 1
Input current range 0 A ... 600 A
https://www.phoenixcontact.com/pi/products/2308098
08/19/2018Page2/4
Universal current transducer-MCR-SL-CUC-600-I-2308098
Technical data
Input data
Overload capacity
3 x I
IN
Frequency measuring range 20 Hz ... 6000 Hz (0 Hz)
Connection method Cable design: 32 mm diameter
Rated frequency: Standard converter 20 Hz ... 6000 Hz
Primary rated current I
pn
600 A
Output data
Output name Current output
Current output signal 4 mA ... 20 mA
Max. output current < 25 mA
Load/output load current output < 300 Ω
Connection method Screw connection
Switching output
Output name No switching output
Power supply
Nominal supply voltage 24 V DC
Supply voltage range 20 V DC ... 30 V DC
Max. current consumption
(30 + I
OUT
) mA
Connection data
Conductor cross section solid min. 0.25 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Stripping length 10 mm
General
Accuracy class 1
Maximum transmission error <± 1 % (of final value)
Temperature coefficient, typical 0.02 %/K (0 ... 60 °C)
0.04 %/K (-40°C...65°C)
Linearity error <± 1 % (From the range end value)
Step response (10-90%) 150 ms
Overvoltage category III
Degree of pollution 2
Rated insulation voltage 300 V AC
Test voltage input/output 3.5 kV (50 Hz, 1 min.)
Test voltage input/power supply 3.5 kV (50 Hz, 1 min.)
Noise emission EN 61000-6-4
https://www.phoenixcontact.com/pi/products/2308098
08/19/2018Page3/4
Universal current transducer-MCR-SL-CUC-600-I-2308098
Technical data
General
Noise immunity EN 61000-6-2
Color green
Housing material Frianyl B63 V0 GV30
Conformance CE-compliant
Standards and Regulations
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Conformance CE-compliant
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Dimensional drawing
90
Ø32
33,8
70
Circuit diagram
IN
1.3
1.4
1.2
1.1
GND
NC
OUTI
+24VDC
ADC
µC
DAC
I
Schematic diagram
A
B

2308098

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Current Transformer Sensors Current Transformers MCR-SL-CUC-600-I
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet