HPP809A031

HTM2500LF – Temperature and Relative Humidity Module
HTM2500LF HPC169 Rev C www.meas-spec.com October 2012
1/9
Hermetic Housing
Humidity calibrated within +/-2% @55%RH
Temperature measurement through NTC
10kOhms +/-1% direct output
Small size product
Typical 1 to 4 Volt DC output for 0 to 100%RH
at 5Vdc
DESCRIPTION
Based on the rugged HTS2035SMD humidity / temperature sensor, HTM2500LF is a dedicated humidity and
temperature transducer designed for OEM applications where a reliable and accurate measurement is needed.
Direct interface with a micro-controller is made possible with the module’s humidity linear voltage output.
FEATURES
Full interchangeability
High reliability and long term stability
Not affected by water immersion
Ratiometric to voltage supply
Suitable for 3 to 10 Vdc supply
voltage
Humidity Sensor Specific Features
Instantaneous de-saturation after long periods in saturation
phase
Fast response time
High resistance to chemicals
Patented solid polymer structure
Temperature Sensor Specific Features
Stable
High sensitivity
APPLICATIONS
Industrial
Process control
Hygrostat
Data logger
HTM2500LF – Temperature and Relative Humidity Module
HTM2500LF HPC169 Rev C www.meas-spec.com October 2012
2/9
PERFORMANCE SPECS
MAXIMUM RATINGS
Ratings Symbol Value Unit
Storage Temperature
Tstg
-
40 to
8
°C
Storage Humidity
RHstg
0 to 100
% RH
Supply Voltage (Peak)
Vs
12
Vdc
Humidity Operating Range
RH
0 to 100
% RH
Temperature Operating Range
Ta
-
40 to
8
°C
Peak conditions: less than 10% of the operating time
ELECTRICAL CHARACTERISTICS
(Ta=23°C, Vs=5Vdc +/-5%, R
L
>1M unless otherwise stated)
Humidity Characteristics Symbol Min Typ Max Unit
Humidity Measuring Range
RH
1
99
%RH
Relative Humidity Accuracy (10 to 95% RH)
RH
+/
-
+/
-
%RH
Supply Voltage
Vs
4.75
5.00
5.25
Vdc
Nominal Output @55%RH (at 5Vdc)
Vout
2.4
2.48
2.54
V
Current consumption
Ic
1.
1.
mA
Temperature Coefficient (10 to 50°C)
Tcc
+0.1
%RH/°C
Average Sensitivity from 33% to 75%RH
Vout/RH
+2
mV/%RH
Sink Current Capability (R
L
=15k)
Is
300
µA
Recovery time after 150 hours of con
densation
tr
10
s
Humidity Hysteresis
+/
-
1.5
%RH
Long term stability
T
+/
-
0.5
%RH/yr
Time Constant (at 63% of signal, static) 33% to 76%RH
(1)
τ
5
s
Output Impedance
Z
70
(1) At 1m/s air flow
(Ta=25°C)
* For temperature upper than 60°C, specific high te mperature cable is required: HTM2500LFL products
Temperature Characteristics
Symbol
Min
Typ
Max
Unit
Nominal Resistance @25°C R 10 k
Beta value: B25/50 β 3347 3380 3413 K
Temperature Measuring Range* Ta -40 85 °C
Nominal Resistance Tolerance @25°C R
N
1 %
Beta Value Tolerance β 1 %
Response Time
τ
10 s
HTM2500LF – Temperature and Relative Humidity Module
HTM2500LF HPC169 Rev C www.meas-spec.com October 2012
3/9
TYPICAL PERFORMANCE CURVES
HUMIDITY SENSOR
Typical response look-up table (Vs = 5V)
RH (%)
Vout (mV)
RH (%)
Vout (mV)
10
1235
55
2480
15
1390
60
2605
20
1540
65
2730
25
1685
70
2860
30
1825
75
2990
35
1960
80
3125
40
2090
85
3260
45
2220
90
3405
50
2350
95
3555
Modeled linear voltage output (Vs = 5V)
Linear Equations
Vout = 26.65 * RH + 1006
RH = 0.0375 * Vout – 37.7
with Vout in mV and RH in %
Polynomial Equations
Vout = 1.05E
-3
*
RH
3
- 1.76E
-1
*
RH
2
+ 35.2 * RH + 898.6
RH = -1.92E
-9
*
Vout
3
+ 1.44E
-5
*
Vout
2
+ 3.4E
-3
*
Vout – 12.4
with Vout in mV and RH in %
Measurement Conditions
HTM2500LF is specified for accurate measurements within 10 to 95% RH.
Excursion out of this range (<10% or >95% RH, including condensation) does not affect the reliability of
HTM2500LF characteristics.
1000
1500
2000
2500
3000
3500
4000
0 10 20 30 40 50 60 70 80 90 100
Relative Humidity (%RH)
Output Voltage (mV)
0
10
20
30
40
50
60
70
80
90
100
1000 1500 2000 2500 3000 3500 4000
Output Voltage (mV)
Relative Humidity (%RH)

HPP809A031

Mfr. #:
Manufacturer:
TE Connectivity / Measurement Specialties
Description:
Industrial Humidity Sensors GAS MEASURE SENSOR HTM2500LF
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet