HLP-80H-24

THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
16ms at full load 230VAC /115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C ( 60% load, 12V model 65% load) ; EN61000-3-3, EAC TP TC 020≧≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria B, EAC TP TC 020
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
316.2Khrs min. MIL-HDBK-217F (25 )
167*53*29.5mm (L*W*H)
0.27Kg; 36pcs/11.2Kg/0.67CUFT
Protection type : Shut down o/p voltage, re-power on to recover
80W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Output constant current level adjustable
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for built in LED lighting system
Suitable for dry / damp locations
100% full load burn-in test
3 years warranty
Features :
HLP-80H series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
14 ~ 17V
59 ~ 68V
87.5%
88.5%
89.5%
90%
90%
90%
90%90% 90%
±2.5% ±2.0% ±1.0% ±1.0% ±1.0%
±1.0%
±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
12V
HLP-80H-12 HLP-80H-15 HLP-80H-20 HLP-80H-24 HLP-80H-30 HLP-80H-36 HLP-80H-42 HLP-80H-48 HLP-80H-54
15V 20V 24V 30V
36V
48V
5A 5A 4A 3.4A
2.7A
2.3A
1.7A
60W 75W 80W 81.6W 81W
82.8W
81.6W
150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
200mVp-p
200mVp-p
54V
1.5A
81W
200mVp-p
42V
1.95A
81.9W
200mVp-p
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
7.2 ~12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V
21.6 ~ 36V
28.8 ~ 48V 32.4 ~ 54V
25.2 ~ 42V
CONSTANT CURRENT REGION
Note.4
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-40 ~ +70 (Refer to "Derating Curve")
EMC IMMUNITY
EMC EMISSION
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer
4 ~ 5A 4 ~ 5A 3.2 ~ 4A 2.72 ~ 3.4A 2.16 ~ 2.7A
1.84 ~ 2.3A
1.36 ~ 1.7A 1.2 ~ 1.5A
1.56 ~ 1.95A
13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V
33 ~ 40V
43 ~ 53V10.8 ~ 13.5V 49 ~ 58V
38 ~ 46V
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13, ,GB19510.14 GB19510.1,
EAC TP TC 004 Design refer to UL60950-1, TUV EN60950-1approved ;
18 ~ 24V
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V 54 ~ 63V
48 ~ 58V
1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. Heat Sink HS1,HS2 can not be shorted.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
File Name:HLP-80H-SPEC 2018-01-09
SELV
MM
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
S
&
E
( except for 48V,54V )( for 48V,54V only)
Mechanical Specification
Unit:mm
fosc : 100KHz
Block Diagram
AC Input Connector (CN1) : JST B6P-VH or equivalent
Pin No.
1
3
6
2,4,5
Assignment
AC/L
AC/N
FG
No Pin
Mating Housing
JST VHR JST SVH-21T-P1.1
or equivalent or equivalent
Terminal
DC Output Connector (CN2) : JST B6P-VH or equivalent
Pin No.
1
2
3,4
5,6
Assignment
DIM+(VR1)
DIM-(VR2)
+V
-V
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
3max.
DIM+
DIM-
DETECTION
PWM & PFC
CIRCUIT
O.L.P.O.T.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
HS1
HS2
230VAC
Input only
AMBIENT TEMPERATURE ( )
-40 -25 0-10 15 30 50 60 70
20
40
50
60
80
100
(HORIZONTAL)
Derating Curve Static Characteristics
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 305
100
90
80
70
60
50
40
LOAD (%)
80W Single Output Switching Power Supply
HLP-80H series
File Name:HLP-80H-SPEC 2018-01-09
29.5max.
53
43
4- 3.5ψ
T3.15A/300V
/350V
CN2
FS1
SVR1
5
3
4
2
1
6
5
3
4
2
1
6
CN1
SVR2
3.5 159.5
167
5
HS1,HS2 can not be shorted
: Grounding required
70
72
74
76
78
80
82
84
86
88
90
92
94
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
277VAC
230VAC
115VAC
0.92
0.93
0.94
0.95
0.96
0.97
0.98
0.99
1
50% 60% 70% 80% 90% 100%
277VAC
230VAC
115VAC
PF
LOAD
Constant Current Mode
HLP-80H series possess superior working efficiency that up to 90% can be reached in field applications.
LOAD
EFFICIENCY (%)
EFFICIENCY vs LOAD (48V Model)
(80W)
80W Single Output Switching Power Supply
HLP-80H series
File Name:HLP-80H-SPEC 2018-01-09
Power Factor Characteristic
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
Typical LED power supply I-V curve
Vo(%)
100
60
50 100
(min.)
Io (%)
Constant
Current area
Hiccup
Protection
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.

HLP-80H-24

Mfr. #:
Manufacturer:
Description:
AC/DC Power Supply Single-OUT 24V 3.4A 81.6W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet