3/13
L9348
Table 2. Thermal Data
Table 3. Absolute Maximum Ratings
The absolute maximum ratings are the limiting values for this device. Damage may occur if this device is
subjected to conditions which are beyond these values.
Note: Human Body Model according to MIL883C. The device withstands ST1 class level.
Table 4. Operating Range.
Symbol Parameter Test Conditions
Values
Unit
Min. Typ. Max.
T
j
Junction temperature -40 150 °C
T
jc
Junction temperature during
clamping (life time)
t = 30min
t = 15min
175
190
°C
°C
T
stg
Storage temperature -55 150 °C
R
th j-case
Thermal resistance junction to
case
2°C/W
Symbol Parameter Test Conditions Value Unit
Voltages
V
S
Supply voltage range -0.3 to 40 V
V
Q
, V
D
max. static Output voltage 40 V
V
IN
, V
EN
Input voltage range
(IN1 to IN4, EN)
|I
I
| < 10mA -1.5 to 6 V
V
ST
Status output voltage range |I
I
| < 1mA -0.3 to 6 V
V
DRmax
max. Reverse breakdown
voltage free wheeling diodes
D3, D4
I
R
= 100 A
55 V
Currents
I
Q 1/2
Output current at reversal
supply for Q1, Q2
-4 A
I
Q 3/4
Output current at reversal
supply for Q3, Q4
-2 A
I
ST
Status output current range -1 to 1 mA
E
Q1/2
max. Discharging energy for
inductive loads per channel
Q1, Q2
T
j
= 25°C 50 mJ
T
j
= 150°C 30 mJ
I
FDmax
max. load current free
wheeling diodes
t < 5ms 3 A
ESD Protection
Supply and Signal pins versus GND 2kV
Output pins (Q
X
, D
X
) versus common ground (=short of
SGND with all PGND)
4kV
Symbol Parameter Test Conditions
Values
Unit
Min. Typ. Max.
V
S
Supply voltage 4.8 18 V
T
j
Junction temperature -40 150 °C