JV-N
–2–
ASCTB189E 201606-T
RATING
1. Coil data
2. Specifications
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
4.5V DC
75%V or less of
nominal voltage
5%V or more of
nominal voltage
44.4mA 101Ω
200mW
150%V of
nominal voltage
6V DC 33.3mA 180Ω
9V DC 22.2mA 405Ω
12V DC 16.7mA 720Ω
18V DC 11.1mA 1,620Ω
24V DC 8.3mA 2,880Ω
48V DC 4.2mA 11,520Ω
100V DC Max. 60 VDC Min. 4 VDC 6 mA 16,600Ω 600mW 110%V
Characteristics Item Specifications
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity (resistive load) 16A 125V AC, 10A 277V AC, 10A 30V DC
Max. switching power (resistive load) 2,770VA, 300W
Max. switching voltage 277V AC, 110V DC (0.3A)
Max. switching current 16A (125V AC), 10A (DC)
Nominal operating power 200mW (4.5 to 48V DC), 600mW (100V DC)
Min. switching capacity (reference value)*
1
100mA, 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 2,500 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
4,500 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 12 ms (4.5 to 48V DC), Max. 8 ms (100V DC) (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 5 ms (excluding contact bounce time) (Without diode)
Mechanical
characteristics
Shock resistance
Functional 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 2.0 mm
Expected life
Mechanical (at 180 times/min.) Min. 2×10
7
Electrical (at 20 times/min.)
Min. 3×10
4
(16A 125V AC), Min. 5×10
4
(10A 277V AC),
Min. 10
5
(10A 30V DC), Min. 10
5
(10A 125V AC)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +70°C –40°F to +158°F (4.5 to 48V DC),
–40°C to +60°C –40°F to +140°F (100V DC),
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Air pressure: 86 to 106kPa
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 8 g .28 oz
1. Max. switching power 2. Coil temperature rise
Sample: JVN1aF-12 V-F, 6 pcs.
point measured: coil inside
Contact current: 16 A
3. Operate/release time
Sample: JVN1aF-12 V-F, 6 pcs.
1
10 100
Contact voltage, V
Contact current, A
1,000
10
16
100
AC resistive load
Ambient temperature 30°C
Ambient temperature 70°C
Coil applied voltage, %V
Temperature rise, °C
80 100 120 140 160
20
10
30
40
50
0
0
80 100 120 140 160
1
2
3
4
5
6
7
8
9
10
Max.
Min.
x
–
Max.
release time
Coil applied voltage, %V
operate & release time, ms
operate time
Min.
x
–