Identification/Classification 1:
(header 1 + top left header bar)
Surge arrester
Identification/Classification 2:
(header 2 + bottom left header bar)
2-electrode arrester
Ordering code:
(top right header bar)
B88069X4951xxxx
a)
Series/Type:
(top right header bar)
ES350XN
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester B88069X4951xxxx
a)
2-electrode arrester ES350XN
KB AB E / KB AB PM Issue 02 / 2007-01-12
Please read Cautions and warnings and Page 2 of 4
Important notes at the end of this document.
Features Applications
Extremely small size
Very fast response time
Stable performance over life
Extremely low capacitance
High insulation resistance
RoHS-compatible
Modem
XDSL-splitter
Tuner
Electrical specifications
DC spark-over voltage
1) 2)
350
± 15
V
%
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 530
< 450
< 600
< 530
V
V
V
V
Service life
10 operations 8/20 µs 2.5 kA
1 operation 8/20 µs 5 kA
Insulation resistance at 100 V
dc
> 1
G
Ω
Capacitance at 1 MHz < 1 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
< 0.5
~ 130
V
A
V
Weight ~ 0.3 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, red positive
ES 350 YY O
ES - Series
350 - Nominal voltage
YY - Year of production
O - Non radioactive
a)
xxxx = C253 (2500 pcs in container)
= T103 (1000 pcs on tape and reel)
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
Surge arrester B88069X4951xxxx
a)
2-electrode arrester ES350XN
KB AB E / KB AB PM Issue 02 / 2007-01-12
Please read Cautions and warnings and Page 3 of 4
Important notes at the end of this document.
Dimensional drawing
Packing advice
T103 = 1000 pcs on tape and reel
Cautions and warnings
Surge arresters must not be operated directly in power supply networks.
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.
Not to scale
Dimensions in mm
Non controlled document

B88069X4951T103

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors ES 350XN
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet