843996-6

Lance Release Tip
Locking Lance
Micro MATE-N-LOCK*
Receptacle Contact
Lance Reset Portion
Handle
© 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
1 of 3
Instruction Sheet
TOOLING ASSISTANCE CENTER
1-800-722-1111
PRODUCT INFORMATION
1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com
LOC B
408-10020
Extraction/Lance Reset Tool
843996-6
09 MAY 11 Rev C
PROPER USE GUIDELINES
Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools. Hand tools are intended for occasional use
and low volume applications. A wide selection of powered application equipment for extended-use, production operations is available.
Figure 1
1. INTRODUCTION
Extraction/Lance Reset Tool 843996-6 is designed to
remove Micro MATE-N-LOK receptacle contacts from
a housing and reset overly depressed contact locking
lances. See Figure 1.
Read these instructions thoroughly before attempting
to re
move any contacts or resetting the locking lance.
NOTE
i
All dimensions are in millimeters (followed by
inches in brackets). Figures and illustrations are for
reference only
, and are not drawn to scale.
Reasons for reissue of this instruction sheet are
provided in Section 5, REVISION SUMMARY.
2. DESCRIPTION
The tool features a handle marked with the part
number, a contact lance release tip, locking lance
reset portion, and tool stop. The contact lance release
tip is designed to depress the contact locking lance to
allow extraction of the contact. The tool stop prevents
over-insertion of the tip. The lance reset portion is
designed to reposition an overly depressed locking
lance to the proper height assuring retention of the
contact in the housing.
3. USING THE TOOL (See Figure 2
3.1. Extraction
1. While holding the housing, grasp the wire at
the back of the housing, and push forward toward
the mating end of the housing to disengage the
contact locking lance from the shoulder of the
circuit cavity.
2. Fully insert the extraction tool tip into the
window adjacent to the circuit cavity until it
bottoms inside the window.
3. Pull back lightly on the wire and, if necessary,
move the tool just enough to release the contact
locking lance.
4. Pull the contact from the housing, then remove
the tool.
408-10020
2 of 3
Rev C
3.2. Locking Lance Reset (See Figure 3)
Check compatibility of the contact and tool, then
proceed as follows:
Wires
Back of
Housing
Tip of Tool
Window
Extraction
1. Orient the lance reset portion so that the taper
is facing the contact locking lance.
Figure 2
Side View
Top View
Reset Locking Lance
Lance Reset
Portion
Contact Locking
Lance
Lance Reset Portion
Contact Locking Lance
Figure 3
2. Keep the lance reset portion against the
contact and slide it towards the base of the
contact locking lance until it bottom
3. Remove the tool. The contact is ready for
re-insertion into the housing.s.
NOTE
i
Damaged contacts should not be used. If a
damaged contact is evident, it should be cut from
the wire and rep
laced with a new one.
4. MAINTENANCE AND INSPECTION
The tool should conform to the dimensions provided in
Figure . It is recommended that each tool be
inspected
upon arrival to be sure it has not been damaged in
tra
nsit and at regularly scheduled intervals to be sure it
remains functional.
Keep the tool clean.
5. REVISION SUMMMARUY
Since the previous release of this instruction sheet,
the new company logo has been applied
Lance Reset Angle
17°
Lance Reset Tip
6.35 [.250]
.081 [.032]
12.7 [.50]
4.57 [.180]
3.81 [.150]
17.17 [.700]
Lance Reset Tip
408-10020
3 of 3
Rev C
Figure 4

843996-6

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Extraction/Lance Reset Tool
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet