File Name:GSM06U-SPEC 2018-03-27
ANSI/AAMI ES60601-1(3.1 version),CAN/CSA-C22 3rd edition, approvedEAC TP TC 004
I/P-O/P:5656VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
500Khrs min. MIL-HDBK-217F(25 )℃
32*66*42.5mm (L*W*H)
100g; 110pcs/12Kg/CARTON
See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
Parameter
Standard
FCC PART 15 & 18 / CISPR22, CAN ICES-3(B)/NMB-3(B)
FCC PART 15 & 18 / CISPR22, CAN ICES-3(B)/NMB-3(B)
Test Level / Note
Class B
Class B
Conducted emission
Radiated emission
SPECIFICATION
6WAC-DC Reliable Green MedicalAdaptor
GSM06U series
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 7)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
PROTECTION
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
1000ms, 50ms, 12ms at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
68% 74% 74% 76% 77% 79% 80% 82%
0.18A / 100VAC
15A / 115VAC 30A / 230VACCold start
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
0 ~ +50 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH℃ non-condensing
±℃℃0.04% / (0 ~ 40 )
OVERLOAD
OVER VOLTAGE
>105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
>120% rated output voltage
Protection type : Clamp by zener diode
5V 7.5V6V 9V 12V 15V 18V 24V
GSM06U05 GSM06U06 GSM06U07 GSM06U09 GSM06U12 GSM06U15 GSM06U18 GSM06U24
1.2A 0.8A1.0A 0.66A 0.5A 0.4A 0.33A 0.25A
0 ~ 1.2A 0 ~ 0.8A0 ~ 1.0A 0 ~ 0.66A 0 ~ 0.5A 0 ~ 0.4A 0 ~ 0.33A 0 ~ 0.25A
6W 6W6W 6W 6W 6W 6W 6W
50mVp-p 80mVp-p50mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p
±5.0%
±5.0%
±5.0%±5.0%
±5.0%±5.0%
±5.0%
±5.0%
±5.0% ±5.0% ±5.0%
±0.5% ±0.5%±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±4.0%
GSM06U05-P1J GSM06U06-P1J GSM06U07-P1J GSM06U09-P1J GSM06U12-P1J GSM06U15-P1J GSM06U18-P1J GSM06U24-P1J
Touch current < 50 A/264VACμ
±3.0% ±3.0% ±3.0% ±2.0%
MTBF
DIMENSION
OTHERS
NOTE
PACKING
CONNECTOR
PLUG
CABLE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 & 47 capacitor.
ffμμ
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
EMC EMISSION