Technical data
Reference standard: IEC / UL 60384-14. All data given at T = 20 °C unless otherwise specified.
Rated AC voltage ( IEC 60384-14 ) 530 V (50/60 Hz)
Maximum continuous DC voltage V
DC
1000 V
Max. operating temperature T
op,max
+110 °C
DC test voltage 2700 V, 2 s
The repetition of this DC voltage test may damage the capacitor. Special care must be taken in
case of use several capacitors in a parallel configuration.
Dissipation factor tan δ (in 10
-3
)
at 20 °C (upper limit values)
C
R
2.2 µF C
R
> 2.2 µF
at 1 kHz 1 2
Insulation resistance R
ins
or time constant τ = C
R
R
ins
at 100 V DC, 20 °C,
rel. humidity 65% and for 60 s
(minimum as-delivered values)
C
R
0.33 µF C
R
> 0.33 µF
30 000 M 10 000 s
Passive flammability category B
Capacitance tolerances
(measured at 1 kHz) ±10% (K), ±20% (M)
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k
0
values
Lead spacing 10 mm 15 mm 22.5 mm 27.5 mm 37.5 mm 52.5 mm
dV/dt in V/µs 550 400 200 150 100 40
k
0
in V
2
/µs 473 000 344 000 172 000 129 000 86 000 34 400
B32911 ... B32918
X1 / 530 V AC
Page 10 of 24Please read Cautions and warnings and
Important notes at the end of this document.
Impedance Z versus frequency f
(typical values)
B32911 ... B32918
X1 / 530 V AC
Page 11 of 24Please read Cautions and warnings and
Important notes at the end of this document.
Testing and Standards
Test Reference Conditions of test Performance
requirements
Electrical
Parameters
IEC 60384-14 Voltage Proof:
Between terminals,
4.3 V
R
, 1 min.
Terminals and enclosure: 2 V
R
+
1500 V AC
Insulation resistance, R
INS
Capacitance, C
Dissipation factor, tan δ
Within specified limits
Robustness of
terminations
IEC 60068-2-21 Tensile strength (test Ua1)
Capacitance and tan δ
within specified limits
Wire diameter
Tensile
force
0.5 < d
1
0.8 mm
0.8 < d
1
1.25 mm
10 N
20 N
Resistance to
soldering heat
IEC 60068-2-20,
test Tb,
method 1A
Solder bath temperature at
260 ± 5 °C, immersion for
10 seconds
C/C
0
5%
tan δ within specified
limits
Rapid change of
temperature
IEC 60384-16 T
A
= lower category temperature
T
B
= upper category temperature
Five cycles, duration t = 30 min.
No visible damage
IC/C
0
I 5%
tan δ within specified
limits
Vibration IEC 60384-14 Test F
C
: vibration sinusoidal
Displacement: 0.75 mm
Accleration: 98 m/s
2
Frequency: 10 Hz ... 500 Hz
Test duration: 3 orthogonal axes,
2 hours each axe
No visible damage
Bump IEC 60384-14 Test Eb: Total 4000 bumps with
400 m/s
2
mounted on PCB
6 ms duration
No visible damage
IC/C
0
I 5%
tan δ within specified
limits
Climatic
sequence
IEC 60384-14
Dry heat T
B
/ 16 h.
Damp heat cyclic, 1st cycle
+ 55 °C / 24h / 95% ... 100% RH
Cold T
A
/ 2h
Damp heat cyclic, 5 cycles
+ 55 °C / 24h / 95% ... 100% rh
No visible damage
IC/C
0
I 5%
Itan δ I 0.008,
C 1 µF
Itan δ I > 0.005,
C > 1 µF
Voltage proof
R
INS
50% of initial limit
B32911 ... B32918
X1 / 530 V AC
Page 12 of 24Please read Cautions and warnings and
Important notes at the end of this document.

B32911A5332M

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Safety Capacitors 0.0033uF 530Vac X1 MKP 20% LS=10mm
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: