VQB100R-T110-S12

cui.com
date 06/18/2015
page
1 of 7
SERIES: VQB100R DESCRIPTION: DC-DC CONVERTER
date 06/18/2015
page
1 of 7
FEATURES
• up to 100 W isolated output
• industry standard quarter brick package
• 3:1 input range (66~160 Vdc)
• single output from 5~24 Vdc
• 2,250 Vdc isolation
• over current, over temperature, over voltage,
and short circuit protections
• remote on/off
• efficiency up to 92%
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise
1
efciency
range
(Vdc) (Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VQB100R-T110-S5 66 ~ 160 5 20 100 100 90
VQB100R-T110-S12 66 ~ 160 12 8.4 100 150 92
VQB100R-T110-S24 66 ~ 160 24 4.2 100 240 91
Notes: 1. ripple and noise are measured at 20 MHz BW with 10µF tantalum capacitor and 1µF ceramic capacitor across output
2. an external input capacitor of 120 µF is recommended to reduce the input ripple voltage.
PART NUMBER KEY
VQB100R-T110 - SXX
Input Voltage Output Voltage
Base Number
For more information, please visit the product page.
cui.com
CUI Inc SERIES: VQB100R DESCRIPTION: DC-DC CONVERTER date 06/18/2015 page 2 of 7
INPUT
parameter conditions/description min typ max units
operating input voltage 66 110 160 Vdc
input surge voltage 100 ms max. 180 Vdc
under voltage lockout
power up
power down
62
56
Vdc
Vdc
start-up time 45 ms
lter PI type
on/off
1
models ON (open circuit or 3.5~75 Vdc)
models OFF (0~1.8 Vdc)
Notes: 1. logic compatibility, open collector reference to –input.
OUTPUT
parameter conditions/description min typ max units
output capacitance
5 Vdc output model
12 Vdc output model
24 Vdc output model
10,000
8,800
1,500
μF
μF
μF
line regulation measured from high line to low line ±0.2 %
load regulation measured from full load to zero load ±0.2 %
voltage accuracy ±1.5 %
adjustability see application notes ±10 %
switching frequency 100% load, input voltage range 200 kHz
transient response 25% step load change
error band
recover time
±5
200
% Vout
µs
temperature coefcient ±0.03 %/°C
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection %Vo 115 140 %
over current protection % nominal output current 110 180 %
short circuit protection continuous
over temperature protection 105 °C
For more information, please visit the product page.
cui.com
CUI Inc SERIES: VQB100R DESCRIPTION: DC-DC CONVERTER date 06/18/2015 page 3 of 7
ENVIRONMENTAL
parameter conditions/description min typ max units
operating case temperature -40 100 °C
storage temperature -55 105 °C
humidity non-condensing 95 %
shock/vibration EN50155 (EN61373)
enviromental EN50155 (EN60068-2-1, EN60068-2-2, EN60068-2-30)
SOLDERABILITY
parameter conditions/description min typ max units
wave soldering see wave soldering prole 260 °C
Notes: 1. Soldering materials: Sn/Cu/Ni
2. Ramp up rate during preheat: 1.4°C/s (from 50°C to 100°C)
3. Soaking temperature: 0.5°C/s (from 100°C to 130°C), 60±20 seconds
4. Peak temperature: 260°C, above 250°C for 3~6 seconds
5. Ramp down rate during cooling: -10°C/s (from 260°C to 150°C)
0
50
100
150
200
250
300
020406080100 120140 160 180
Time (Seconds)
Temperature (°C)
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output
input to case
output to case
2,250
2,250
1,500
Vdc
Vdc
Vdc
isolation resistance 10 MΩ
isolation capacitance 1,000 pF
safety approvals UL 60950-1
EMC EN50155 (EN50121-3-2) (external circuit required, see Figure 1)
EMI EN55011 Class A
ESD
EN61000-4-2 Air ±8 kV Class B
EN61000-4-2 Contactr ±6 kV Class A
radiated immunity EN61000-4-3 10 V/m Class A
EFT/burst EN61000-4-4 ±2 kV Class A
surge EN61000-4-5 ±1 kV Class B
conducted immunity EN61000-4-6 10 Vr.m.s Class A
RoHS 2011/65/EU
For more information, please visit the product page.

VQB100R-T110-S12

Mfr. #:
Manufacturer:
Description:
Isolated DC/DC Converters dc-dc isolated, 100 W, 66 160 Vdc input, 12 Vdc, 8.4 A, single output, DIP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS