RSP-2000-24

Function Manual
EXTERNAL VOLTAGE (DC)
PIN3 PV
PIN4 GND
1. Remote Sense
Sense lines should be twisted in pairs to minimize noise pick-up.
The Remote Sense compensates voltage drop on the load wiring up to 0.5V
The signal should be connected to the positive terminal of the load whereas signal to the negative terminal.+S -S
LOAD
-V
+V
PIN2 -S
PIN1 +S
3. Remote ON-OFF Control
The power supply can be turned ON/OFF individually or along with other units by using the "Remote ON-OFF" function.
PIN7 Remote ON-OFF
PIN11 +5V-AUX
Between andRemote ON-OFF +5V-AUX
Switch Short
Switch Open
Power Supply Status
ON
OFF
switch
File Name:RSP-2000-SPEC 2018-01-15
2000W Power Supply with Single Output
RSP-2000 series
+S +V -S -V& , & also need to be connected on CN501.
30
40
60
OUTPUT VOLTAGE(%)
EXTERNAL VOLTAGE (DC)
80
100
115
Vout
0.40
for 12V model
for 24V,48V
model
1 2 3 4 4.7 5
V
40 60 80 100 115
V
100
40
60
87
20
OUTPUT CURRENT (%)
OUTPUT VOLTAGE (%)
20
Non-Linear
In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~115% of the nominal voltage by applying
EXTERNAL VOLTAGE.
2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
The rated current should change with the
Output Voltage Programming accordingly.
PIN2 -S
PIN1 +S
+V
CN501
CN501
CN501
+V
+V
-V
-V
-V
4.Current Sharing with Remote Sense
DA,DB and GND are connected mutually in parallel.
Difference of output voltages among parallel units should be less than 0.2V.
CN502/CN504 Function pin connection
V is CN502/CN504 connected to plug pin, X is CN502/CN504 not connected to plug pin.
Parallel
CN502 CN502 CN502 CN502CN504 CN504 CN504 CN504
PSU1 PSU2 PSU3 PSU4
1 unit
X
X
XX
V
VVV
VV
V
V
VV
V
VV
VVV
2 unit
3 unit
4 unit
PSU1
RSP-2000 RSP-2000 RSP-2000 RSP-2000
PSU2 PSU3 PSU4
+V
If the lines of CN502 are too long, they should
be twisted in pairs to avoid the noise.
-V
LOAD
TB1 TB1 TB1 TB1
CN502 CN502 CN502 CN502
CN504 CN504 CN504 CN504
-V -V -V -V+V +V +V +V
1111
2222
5555
6666
Fig 4.1
2000W Power Supply with Single Output
RSP-2000 series
File Name:RSP-2000-SPEC 2018-01-15
DA DA DA DADB DB DB DBGND GND GND GND
333311115555
DA DA DA DADB DB DB DBGND GND GND GND
PSU2 CN502 PSU3 CN502 PSU4 CN502
PSU1 CN502
222244446666
RSP-2000 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below :
The total output current must not exceed the value determined by the following equation:
The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
Under parallel operation, the minimum output load should be greater than 5% of total output load; otherwise, it is likely that only one unit operates
whereas other units may enter standby mode or their LED status indicators may not turn on.
Maximum output current at parallel operation=(Rated current per unit) (Number of unit) 0.9××
×When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit) (Number of unit)
the current shared among units may not be fully balanced.
2000W Power Supply with Single Output
RSP-2000 series
Mechanical Specification
Case No. 952D Unit:mm
TB1
3
CN502
2
1
7
-V
+V
20.5
Air flow
direction
41
127
18.5
3-M4 L=4
90
10
6
271
25.4
7.8
21 34.5
59
295
271
25.47.8
6
20.5
3-M4 L=6
3-M4 L=6
1
2
11
12
CN501
CN504
SVR
12
34
56
Pin No.
1
2
5
6
11
Function
DC-OK
+S
-S
T-ALARM
+5V-AUX
Description
High (4.5 ~ 5.5V) : When the Vout 80% 6%.≦±
Low (0 ~ 0.5V) : When Vout 80% 6%.≧±
The maximum sourcing current is 10mA and only for output. (Note.2)
Positive sensing for remote sense.
Negative sensing for remote sense.
High : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm.(4.5 ~ 5.5V)
Low (0 ~ 0.5V) : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. The maximum sourcing
current is 10mAand only for output. (Note.2)
Auxiliary voltage output, 4.5~5.5V, referenced to .GND-AUX
The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the Remote ON-OFF control.
3
4GND
PV
This pin connect to the negative terminal(-V).
Connection for output voltage . (Note.1)programming
7
Remote
ON-OFF
The unit can turn the output on and off by electrical signal or dry contact between Remote and . (Note.2)ON-OFF +5V-AUX
Short (4.5 ~ 5.5V) : Power OFF ; Open (0 ~ 0.5V) : Power ON ; The maximum input voltage is 5.5V.
8,9,10
GND-AUX
Auxiliary voltage output GND.
The signal return is isolated from the output terminals (+V & -V).
12 +12V-AUX
Auxiliary voltage output, 10.6~13.2V, referenced to .GND-AUX
The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by the Remote ON-OFF control.
Note1: Non-isolated signal, referenced to the output terminals (-V).
Note2: Isolated signal, referenced to .GND-AUX
1
2
11
12
Control Pin No.Assignment : HRS DF11-12DP-2DS or equivalent(CN501)
Mating Housing
Terminal
HRS DF11-12DS or equivalent
HRS DF11-**SC or equivalent
1
1 1
2
2
2
1
Mounting Screw
Mounting Surface
Chassis of RSP-2000
L
File Name:RSP-2000-SPEC 2018-01-15
Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque
1
2
6mm
4mm
M4
M4
7~1 Kgf-cm0
7~1 Kgf-cm0
2-M5

RSP-2000-24

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 1920W 24V 80A Front End PS w/PFC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet