Input:
AC Input Voltage Range
108VAC to 304VAC
Nominal AC Input Voltage
120 to 277VAC
AC Input Frequency
47~63Hz
Maximum Input Current
≤ 1.26A
Leakage Current
0.75mA maximum at 120VAC Input
Inrush Current
< 80A
OUTPUT:
Power Factor
≥ 0.9
Output Current Ripple
<105mA (p-p)
Efficiency
Turn-on Delay Time
<0.5s maximum at nominal AC Power ON
Environmental:
Temperature
Operation Tc -40 to 83°C
Non-operation -40 to +90°C
Operating Humidity 5 to 98%
Dimming Grounding
Dim(-) and Vout(-) must never be connected
together to ensure proper operation and isolation
requirements
EMC
FCC Part 15 Class A
Immunity
IEC61000-4-2
IEC61000-4-5
IEC61000-4-11
IEC61000-3-2 Class C
Input Over Current Protection
The input power line will be fused with a 3.15A fuse
Short-Circuit Protection
The Driver will withstand a short circuit across the outputs
without damage.
Over Temperature Protection
The load will drop by 50% automatically if the case
temperature exceeds the recommended limit.
Over Voltage Protection
During no load condition, the over voltage protection
trigger level should be less than 195Vrms.
Dielectric Withstand (Hi-pot) Test
Primary to secondary: 4242VDC for 1 minute, 5.5mA
Insulation Resistance
Primary to secondary: >5M Ohm 500VDC, 1 Minute
Wire Connections
Warranty
5 Years