FN284-10-06

DATASHEET
IEC Inlet Filters FN 280
Compact filtered power entry module
Complies with IEC/EN 60601-1
Rated currents up to 10 A
Single or dual-fuse holder
Fuses Ø5 x 20 mm
2-pole rocker switch
General purpose application
Optional earth line choke (E type)
Optional medical versions (B type)
Performance indicators
Technical specifications
Maximum continuous operating voltage
250 V, 50/60 Hz
Operating frequency
DC to 400 Hz
Rated currents
1 to 10 A @ 40°C max.
High potential test voltage
P –> PE 2000 VAC for 2 sec (standard types)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 760 VAC for 2 sec
Protection category
IP 40 according to IEC 60529
Temperature range (operation and storage)
-25°C to +85°C (25/85/21)
Design corresponding to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Flammability corresponding to
UL 94 V-2 or better
MTBF @ 40°C/230 V (Mil-HB-217F)
1,500,000 hours
Fuse holder
1 or 2 fuses (Ø5 x 20 mm)
Marking
max. 250 V ~ (text is print. below fuse symbol)
Rocker switch description
Function
2-pole, dark not illuminated
Marking I - 0
Electrical specifications
Inrush current 82 A
6,000 on-off operations according to UL 1054, TV5
10,000 on-off operations according to ENEC
Switch ratings
USA (UL) and Canada (C-UL)
10 A, 125 VAC; 10 A, 250 VAC; 1/3 HP
Europe (ENEC)
10 A (4 A), 250 VAC*
Mechanical life
50,000 cycles
* Value in () relates to the inductive current charge: cosφ = 0.65
Approvals
(CQC except HI-types)
The FN 280 power entry module combines an IEC
inlet, a mains filter with single or dual- fuse holder and
a 2-pole rocker switch in a small form factor.
Choosing FN 280 product line brings you the rapid
availability of a standard filter associated with the
necessary safety acceptances. Standard IEC
connector filters are a practical solution helping you
to pass EMI system approval in a short time. A wide
selection on amperage ratings, fuse options,
mounting possibilities and filters for medical
applications are designed to offer you the desired
solution.
Features and benefits
High conducted attenuation performance, based
on chokes with high saturation resistance and
excellent thermal behavior
Rear/front or snap-in mounting
Single or dual-fuse holder
2-pole rocker switch
Custom-specific versions are available on request
Typical applications
Portable electrical and electronic equipment
Consumer goods
EDP and office equipment
Single-phase power supplies, switch-mode power
supplies
Test and measurement equipment
Medical equipment
Typical electrical schematic
2 EMC/EMI Products Schaffner Group Datasheets 2018
Filter selection table
Filter Rated current Leakage current** Inductance Capacitance Resistance Output Fuses** Weight
@ 40°C (25°C) @ 230 VAC/50 Hz L1 L2 Cx Cy R connections
[A] [μA] [mH] [mH] [nF] [nF] [kΩ] [Qty] [g]
FN 281-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 140
FN 281-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 140
FN 281-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 140
FN 281-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 140
FN 281-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 140
FN 282-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90
FN 282-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90
FN 282-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90
FN 282-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90
FN 282-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 140
FN 283-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 140
FN 283-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 140
FN 283-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 140
FN 283-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 140
FN 283-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 140
FN 284-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90
FN 284-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90
FN 284-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90
FN 284-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90
FN 284-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 140
FN 285-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 140
FN 285-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 140
FN 285-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 140
FN 285-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 140
FN 285-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 140
FN 286-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90
FN 286-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90
FN 286-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90
FN 286-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90
FN 286-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 140
FN 283 E-1-06 1 (1.2) 373 7.5 0.4 220 2.2 1000 -06 1 140
FN 283 E-2-06 2 (2.4) 373 2 0.4 220 2.2 1000 -06 1 140
FN 283 E-4-06 4 (4.8) 373 1 0.4 220 2.2 1000 -06 1 140
FN 283 E-6-06 6 (7.2) 373 0.45 0.4 220 2.2 1000 -06 1 140
FN 284 E-1-06 1 (1.2) 373 7.5 0.4 220 2.2 1000 -06 2 90
FN 284 E-2-06 2 (2.4) 373 2 0.4 220 2.2 1000 -06 2 90
FN 284 E-4-06 4 (4.8) 373 1 0.4 220 2.2 1000 -06 2 90
FN 284 E-6-06 6 (7.2) 373 0.45 0.4 220 2.2 1000 -06 2 90
FN 282 B-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90
FN 282 B-2-06 2 (2.4) 2 2 220 1000 -06 2 90
FN 282 B-4-06 4 (4.8) 2 1 220 1000 -06 2 90
FN 282 B-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90
FN 282 B-10-06 10 (11.6) 2 0.34 220 1000 -06 2 140
* Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
** Filters are delivered without fuse.
3 EMC/EMI Products Schaffner Group Datasheets 2018
Filter Rated current Leakage current** Inductance Capacitance Resistance Output Fuses** Weight
@ 40°C (25°C) @ 230 VAC/50 Hz L1 L2 Cx Cy R connections
[A] [μA] [mH] [mH] [nF] [nF] [kΩ] [Qty] [g]
FN 284 B-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90
FN 284 B-2-06 2 (2.4) 2 2 220 1000 -06 2 90
FN 284 B-4-06 4 (4.8) 2 1 220 1000 -06 2 90
FN 284 B-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90
FN 284 B-10-06 10 (11.6) 2 0.34 220 1000 -06 2 140
FN 286 B-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90
FN 286 B-2-06 2 (2.4) 2 2 220 1000 -06 2 90
FN 286 B-4-06 4 (4.8) 2 1 220 1000 -06 2 90
FN 286 B-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90
FN 286 B-10-06 10 (11.6) 2 0.34 220 1000 -06 2 140
* Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
** Filters are delivered without fuse.
Product selector
For example: FN 281-6-06, FN 283 B-04-06, FN 283 E-1-06
Typical filter attenuation
Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym; C=0.1 Ω/100 Ω sym; D=100 Ω/0.1 Ω sym
1 A types
2 to 6 A types
10 A types

FN284-10-06

Mfr. #:
Manufacturer:
Description:
AC Power Entry Modules 10A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: