Pressure Sensors 40PC Series
Miniature Signal Conditioned
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
31
FEATURES
1 Smallest amplified sensor package
1 Minimal PCB space
1 Fully signal conditioned
1 Operating temperature range from −45° to +125°C
1 Silicon piezoresistive technology
1 Monolithic design
1 6 Pin DIP package
1 Port designed for O-ring interface
1 Excellent media compatibility
1 Accuracy of 0.2%
PERFORMANCE CHARACTERISTICS
Pressure Range ±50 mm Hg 0-15 psi 0-100 psi 0-150 psi 0-250 psi
Overpressure, max. ±170 mm Hg 45 psi 200 psi 300 psi 500 psi
Supply Voltage 5 VDC ±0.25
Supply Current 10 mA max.
Output Source Current 0.5 mA max.
Output Sink Current 1.0 mA max.
Operating Temperature −45° to +125°C (−49° to +257°F)
Storage Temperature −55° to +125°C (−67° to +257°F)
Hysteresis & Repeatability 0.15% Span, Typ.
Ratiometricity (at 4.75 to
5.25 Supply Voltage) ±0.25% Span, Typ.
Output Load Capacitance 0.05 microtarads, max.
Full Scale
−50 mm Hg 0.50 VDC Typ.
+50 mm Hg 4.50 VDC Typ.
All other pressure ranges 4.50 VDC Typ.
Media DRY GASES ONLY: Media must be compatible with
Compatibility P1 port epoxy based adhesive
Media must be compatible with glass, silicon,
P2 port stainless steel, invar, Sn/Ni plating or Sn/Ag solder
40PC SERIES ORDER GUIDE
Catalog
Listing
Pressure Range
psi
Pressure
Type Lead Style
40PC001B1A ±50 mm Hg Bi-directional 1-unformed
40PC001B2A ±50 mm Hg Bi-directional 2-formed away from port
40PC001B3A ±50 mm Hg Bi-directional 3-formed towards port
40PC015G1A 0-15 Gage 1-unformed
40PC015G2A 0-15 Gage 2-formed away from port
40PC015G3A 0-15 Gage 3-formed towards port
40PC100G1A 0-100 Gage 1-unformed
40PC100G2A 0-100 Gage 2-formed away from port
40PC100G3A 0-100 Gage 3-formed towards port
40PC150G1A 0-150 Gage 1-unformed
40PC150G2A 0-150 Gage 2-formed away from port
40PC150G3A 0-150 Gage 3-formed towards port
40PC250G1A 0-250 Gage 1-unformed
40PC250G2A 0-250 Gage 2-formed away from port
40PC250G3A 0-250 Gage 3-formed towards port
Note: For tubing and O-Ring interface recommendations, see the 40PC Application Note in the Reference Section.
Amplified