PA-3
REV.: 7/2016www.recom-power.com
AC/DC Converter
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range
(6)
230VAC, with derating (see graph) -40°C to +85°C
Maximum Case Temperature +105°C
Thermal Impedance 8.5°C/W typ.
Humidity non-condensing 5% - 95%, RH max.
Vibration MIL-STD-202G
MTBF
(7)
MIL-HDBK-217F, 115VAC, +25°C
MIL-HDBK-217F, 230VAC, +25°C
2238 x 10
3
hours
1670 x 10
3
hours
-40 60 70
75
80
85
90 10050403020100-20
-25
0
20
40
60
50
80
100
Ambient Temperature [°C]
Output Power [%]
Output Power [%]
@ 85-140VAC
3.3V and 5V
all other models
-40 60 70
75
80
85
90 10050403020100-20
0
20
40
60
50
80
100
Ambient Temperature [°C]
@ 140-305VAC
all models
Derating Graph
Specifications (measured @ ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
RAC02-SE/277
Series
Notes:
Note6: At low input voltage (85-140VAC) and temperature below -25°C the RAC02-3.3SE/277 and RAC02-05SE/277, will not start.
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety (LVD)
LVD1208051
IEC60950-1, 2nd Edition, 2009
EN60950-1, 2nd Edition, 2011
Information Technology Equipment, General Requirements for Safety E224736-X1-A24
UL60950-1, 2nd Edition, 2014
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition 2014
Household and similar electrical appliances, General requirements L0339L26-B2 EN60335-1, 2014
EMC Compliance Condition Standard / Criterion
Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement
Report: 1502CE17
EN55022, Class B
EN55024
ESD Electrostatic discharge immunity test ±8kV Air Discharge; ±6kV Contact
Radiated, radio-frequency, electromagnetic field immunity test
3V/m EN61000-4-3, Criteria A
Fast Transient and Burst Immunity
AC Power Port: ±1kV EN61000-4-4, Criteria B
Surge Immunity
AC Power Port: line to line: ±1kV EN61000-4-5, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields
AC Power Port: 3V/m EN61000-4-6, Criteria A
Power Magnetic Field Immunity
1 A/m EN61000-4-8, Criteria A
Voltage Dips and Interruption
Voltage Dips: >95% reduction
>30% reduction
Interruption: >95%
EN61000-4-11, Criteria B
EN61000-4-11, Criteria C
Voltage Fluctuations and Flicker in Public Low-Voltage Systems EN61000-3-3