cui.com
date 12/16/2015 │ page 2 of 5CUI Inc │ SERIES: SWI6-E │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 0.19 A
inrush current at 240 Vac, full load, 25°C, cold start 60 A
leakage current 0.25 mA
no load power consumption 0.1 W
OUTPUT
parameter conditions/description min typ max units
regulation ±5 %
hold-up time at full load 10 ms
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection output shut down
over current protection outputshutdown,autorecovery
short circuit protection outputshutdown,autorecovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute 3,000 Vac
isolation resistance input to output at 500 Vdc 10 MΩ
EMI/EMC CE
MTBF asperTelcordiaSR-332,25°C 300,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -20 60 °C
operatinghumidity non-condensing 20 80 %
storagehumidity non-condensing 10 90 %
For more information, please visit the product page | For information on related products, view Dc Power Jacks