AC PLUG-EU

GE12 05-P1J GE12 07-P1J GE12 09-P1J GE12 12-P1J GE12 15-P1J GE12 18-P1J GE12 24-P1J
I
IIIIIII
IIIIII
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
POWER SUPPLY MAIN BODY ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
LIFE
DIMENSION
OTHERS
DC OUTPUT
NOTE
PLUG
CABLE
OVERLOAD
OVER VOLTAGE
9V7.5V5V 12V 15V 18V 24V
1.33A1.33A2.0A 1.0A 0.8A 0.83A 0.625A
CURRENT RANGE 0 ~ 1.33A0 ~ 1.33A0 ~ 2.0A 0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.83A 0 ~ 0.625A
RIPPLE & NOISE (max.)
Note.3 100mVp-p75mVp-p50mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±3.0% ±3.0%
±1.0% ±1.0% ±1.0%
±5.0%
±5.0%
±5.0%
±5.0%
±1.0% ±1.0%
±5.0%
±5.0%
±3.0%
±3.0%
±1.0%
±3.0%
±3.0%
±1.0%
±3.0% ±3.0%
4000ms, 100ms, 30ms / 230VAC 4000ms, 100ms, 10ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
0.4A / 100VAC 0.25A / 230VAC
COLD START 40A / 100VAC 80A / 230VAC
0.25mA / 240VAC
110% ~ 200% rated output power
115% ~ 135% rated output voltage
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
100Khrs min. MIL-HDBK-217F (25 )
2 years : 100% load 30 , 8 hours / day
-10 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃0.03% / (0 ~ 30 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved
70.7*40*38.8mm (L*W*H)
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug.
CONNECTOR
GE12 05 GE12 07 GE12 09 GE12 12 GE12 15 GE12 18 GE12 24
RATED POWER 12W 12W12W10W10W 15W 15W
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
Features :
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode
ENVIRONMENT
PROTECTION
12WAC-DC Interchangeable Industrial Adaptor
GE12 series
Interchangeable AC plugs (plug kit sold separately)
Universal AC input / Full range
No load power consumption< 0.075W
Energy efficiency Level
Comply with EISA 2007/DoE and EU ErP
Class power (without earth pin)II
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
LED indicator for power on
2 years warranty
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
PACKING
97g ; 50pcs / 6.3kg / CARTON
File Name:GE12-SPEC 2015-09-15
84%82%80% 84% 85%
85% 85.5%
SPECIFICATION
TYPE
ORDER NO.
Australian type U.K type European type US type
Mix four type
AC plug-AU AC plug-UK AC plug-EU AC plug-US
AC plug-MIX
Interchangeable AC plug specifically for GE series
EMC IMMUNITY
EMC EMISSION
Mechanical Specification
File Name:GE12-SPEC 2015-09-15
Static Characteristics
11 0.5mm±
40
70.7
38.8
29.8
AMBIENT TEMPERATURE ( )
90 100 120115 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
95
INPUT VOLTAGE (VAC) 60Hz
ID 2.1 x OD 5.5
InsideOutside
AWM2468 16AWG 1000 for 5~12V
±
50mm
AWM2468 18AWG 1500 for 15~48V
±
100mm
Derating Curve
Unit:mm
LOAD (%)
-10 10 20 30 40
75
50
100
50
C"+"
12WAC-DC Interchangeable Industrial Adaptor
GE12 series
Plug Assignment
Standard plug: P1J
P/N
CENTER
OUTPUT
+
P1J

AC PLUG-EU

Mfr. #:
Manufacturer:
Description:
Plug-In AC Adapters Wall Mount AC Adapters EU PLUG FOR ADAPTER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: