FN258L-7-07

DATASHEET
3-Phase Filters FN 258
Book-style EMC/RFI Filter for Inverters and Power Drive Systems
Industry standard EMC solution for three-phase
PDS filtering
Slim space-saving book-style housing
Solid safety connector blocks or optional wire
output connections
Excellent attenuation performance
HV versions for up to 690 VAC
HVIT versions for IT distribution networks
P/L versions with low leakage current
Performance indicators
Technical specifications
Maximum continuous operating voltage
3x 520/300 VAC (FN 258, FN 258 L, FN 258 P)
3x 760/440 VAC (FN 258 HV, FN 258 HVIT)
Rated currents
7 to 250 A @50°C (480 V filters)
Operating frequency
DC to 60 Hz
High potential test voltage
P –> E 2650 VDC for 2 sec (FN 258)
P –> P 2100 VDC for 2 sec (FN 258)
P –> E 2000 VAC for 2 sec (FN 258L)
P –> P 2100 VDC for 2 sec (FN 258L)
P –> E 3000 VDC for 2 sec (FN 258P)
P –> P 2100 VDC for 2 sec (FN 258P)
P –> E 3200 VDC for 2 sec (FN 258HV and FN 258HVIT)
P –> P 3270 VDC for 2 sec (FN 258HV and FN 258HVIT)
Protection category
IP 20
Overload capability
4x rated current at switch on,
1.5x rated current for 1 minute, once per hour
Temperature range (operation and storage)
-25°C to +100°C (25/100/21)
Flammability corresponding to
UL 94 V-2 or better
Design corresponding to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
MTBF @ 50°C/400 V (Mil-HB-217F)
220,000 hours
Approvals
UL/CSA: FN 258 up to 180 A (ex. -180-07)
Features and benefits
FN 258 range of filters provides state-of- the-art EMI
attenuation based on an innovative multi-stage
filter topology. They help to ensure compliance with
Class A or even Class B limits
The slim book-style shape allows a convenient and
space-saving installation next to inverters and
motor drives
With 480 VAC rating and filter modules from 7 to
250 A, FN 258 are ready for the most diverse
applications worldwide
FN 258 HV filters up to 130 A are designed for 690
VAC distribution networks
FN 258 HVIT filters up to 130 A meet the special
requirements for the application in industrial 690
VAC IT distribution networks
FN 258 L and FN 258 P filters help to fulfill tough
requirements in respect of leakage current
limitation and provide an excellent solution to
overcome problems with nuisance tripping of
sensitive earth leakage detectors
Typical applications
Three-phase variable speed drives and power drive
systems (PDS)
IT power distribution networks (FN 258 HVIT)
Applications comprising energy conversion devices
(inverters, converters)
Process automation equipment
Three-phase power supplies and UPS
Applications with low-leakage current requirements
(FN 258 L and FN 258 P)
Typical electrical schematic
2 EMC/EMI Products Schaffner Group Datasheets 2018
Filter selection table
Filter* Rated current Typical drive Leakage current*** Power loss Input Output Weight
@ 50°C (40°C) power rating** @ 520/760 VAC/50 Hz @ 25°C/50 Hz connections connections
[A] [kW] [mA] [W] [kg]
FN 258-7-.. 7 (7.7) 4 2.0 9 -29 -07 -29 1.0
FN 258-16-.. 16 (17.5) 7.5 2.1 20 -29 -07 -29 1.4
FN 258-30-.. 30 (33) 15 2.9 21 -33 -07 -33 1.7
FN 258-42-.. 42 (46) 22 3.0 30 -33 -07 -33 2.5
FN 258-55-.. 55 (60) 30 3.0 30 -34 -07 -34 2.9
FN 258-75-34 75 (82) 37 3.0 24 -34 -34 3.9
FN 258-100-35 100 (110) 55 3.0 51 -35 -35 5.5
FN 258-130-35 130 (143) 75 3.5 50 -35 -35 6.9
FN 258-180-.. 180 (197) 90 3.5 73 -40 -07 -40 11.0
FN 258-250-.. 250 (275) 132 3.4 79 -40 -07 -40 12.0
FN 258 HV-7-29 7 (7.7) 5.5 1.6 9 -29 -29 1.0
FN 258 HV-16-29 16 (17.5) 11 2.3 20 -29 -29 1.5
FN 258 HV-30-33 30 (33) 22 2.3 21 -33 -33 1.8
FN 258 HV-42-33 42 (46) 30 2.6 30 -33 -33 2.6
FN 258 HV-55-34 55 (60) 45 2.6 30 -34 -34 3.0
FN 258 HV-75-34 75 (82) 55 2.6 24 -34 -34 4.3
FN 258 HV-100-35 100 (110) 90 2.6 51 -35 -35 5.6
FN 258 HV-130-35 130 (143) 110 2.9 50 -35 -35 7.1
FN 258 HVIT-7-29 7 (7.7) 5.5 0.1 9 -29 -29 1.0
FN 258 HVIT-16-29 16 (17.5) 11 0.1 20 -29 -29 1.5
FN 258 HVIT-30-33 30 (33) 22 0.1 21 -33 -33 1.8
FN 258 HVIT-42-33 42 (46) 30 0.1 30 -33 -33 2.6
FN 258 HVIT-55-34 55 (60) 45 2.6 30 -34 -34 3.0
FN 258 HVIT-75-34 75 (82) 55 2.6 24 -34 -34 4.3
FN 258 HVIT-100-35 100 (110) 90 2.6 51 -35 -35 5.6
FN 258 HVIT-130-35 130 (143) 110 2.9 50 -35 -35 7.1
FN 258 L-7-.. 7 (7.7) 4 0.1 9 -29 -07 -29 1.0
FN 258 L-16-.. 16 (17.5) 7.5 0.1 20 -29 -07 -29 1.4
FN 258 L-30-.. 30 (33) 15 0.1 21 -33 -07 -33 1.7
FN 258 L-42-.. 42 (46) 22 0.1 30 -33 -07 -33 2.5
FN 258 L-55-.. 55 (60) 30 0.1 30 -34 -07 -34 2.9
FN 258 L-75-34 75 (82) 37 0.1 24 -34 -34 3.9
FN 258 L-100-35 100 (110) 55 0.1 51 -35 -35 5.5
FN 258 L-130-35 130 (143) 75 0.1 50 -35 -35 6.9
FN 258 L-180-.. 180 (197) 90 0.1 73 -40 -07 -40 11.0
FN 258 L-250-07 250 (275) 132 0.1 79 -40 -07 12.0
FN 258 P-7-.. 7 (7.7) 4 0.4 9 -29 -07 -29 1.0
FN 258 P-16-.. 16 (17.5) 7.5 0.4 20 -29 -07 -29 1.4
FN 258 P-30-.. 30 (33) 15 0.4 21 -33 -07 -33 1.7
FN 258 P-42-.. 42 (46) 22 0.4 30 -33 -07 -33 2.5
FN 258 P-55-.. 55 (60) 30 0.4 30 -34 -07 -34 2.9
FN 258 P-75-34 75 (82) 37 0.4 24 -34 -34 3.9
FN 258 P-100-35 100 (110) 55 0.4 51 -35 -35 5.5
FN 258 P-130-35 130 (143) 75 0.4 50 -35 -35 6.9
FN 258 P-180-.. 180 (197) 90 0.4 73 -40 -07 -40 11.0
FN 258 P-250-07 250 (275) 132 0.4 79 -40 -07 12.0
*
**To compile a complete part number, please replace the -.. with the required output connection style.
**
*Calculated at rated current, 440 VAC (FN 258)/690 VAC (FN 258 HV ) and cos phi=0.8. The exact value depends upon the efficiency of the drive, the motor and the entire
***application.
*** Standardized calculated leakage current acc. IEC60939 under normal operating conditions (FN 258 at 520 VAC and FN 258 HV at 760 VAC).
3 EMC/EMI Products Schaffner Group Datasheets 2018
Typical filter attenuation
Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym; C=0.1 Ω/100 Ω sym; D=100 Ω/0.1 Ω sym
7 to 30 A types
42 to 100 A types
130 A types
180 and 250 A types
Note: typical attenuation performance of FN 258 standard filters. The behavior of FN 258 HV, FN 258 HVIT, FN 258 P and FN 258 L may be slightly different.
Mechanical data
7 to 55 A types (-07) 7 to 130 A types (-29, -33, -34, -35)
180 and 250 A types (-07) 180 and 250 A types (-40)
Note: in favour of a better readability, connectors and earth studs are not shown in the horizontal projection.

FN258L-7-07

Mfr. #:
Manufacturer:
Schaffner
Description:
Power Line Filters 7A 9W -LOW LEAKAGE BOOK-STYLE EMC/RFI
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: