RKZ-122005D/P

ECO-1
REV.: 2/2017www.recom-power.com
2 Watt
SIP7 for
SIC Application
DC/DC Converter
Features
Unregulated
Converters
Power Sharing
High Isolation 3kVDC & 4kVDC for 1 minute
Efficiency up to 87%
Wide Operating Temperature Range from -40°C to +85°C
UL60950 Certified
IEC/EN60950-1 Certified
RKZ-xx2005D
Description
The RKZ-xx2005D series features DC/DC converters which are especially designed for SiC mosfet
drivers. The modules are available with input voltages of 5, 12, 15, or 24VDC with two
asymmetric outputs of +20VDC and -5VDC. A special feature of this converter is output power
sharing: the RKZ-xx2005D can be used with equal power (asymmetrical current) or equal current
(asymmetrical power) loads. The modules offer 3kVDC or 4kVDC isolation. The operating
temperature range of -40C to +100°C (with derating) meets harsh environmental requirements.
Selection Guide
Part Input Output Output Efficiency typ. max. Capacitive
Number Voltage Voltage Current typ. Load
(1)
(VDC) (VDC) (mA) (%) (µF)
RKZ-052005D 5 20/-5
50/-200 86
100/1500
+/-80 85
RKZ-122005D 12 20/-5
50/-200
86 100/1500
+/-80
RKZ-152005D 15 20/-5
50/-200
86 100/1500
+/-80
RKZ-242005D 24 20/-5
50/-200
87 100/1500
+/-80
3
Y
E
A
R
w
a
r
r
a
n
t
y
3
Notes:
Note1: Max. capacitive load is tested at nominal input voltage and full load.
Input Voltage
Output Voltage
Model Numbering
RKZ-__2005D/_ _
Notes:
Note2: without suffix, standard 3kVDC isolation
add suffix “/H” for higher 4kVDC isolation
Note3: without suffix, without Short Circuit Proetction
add suffix “/P” for continuous short circuit protection
Examples:
RKZ-052005D = 5Vin, 20/-5Vout, without SCP function + standard 3kVDC isolation
RKZ-12005D/HP = 12Vin, 20/-5Vout, with continuous SCP function + high 4kVDC isolation
Protection
(3)
Isolation
(2)
Dual Output
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range -10% +10%
Operating Frequency
20kHz
Minimum Load 0%
Output Ripple and Noise
(4)
70mVp-p 150mVp-p
continued on next page
Notes:
Note4: Ripple and Noise is measured with a 20MHz badnwidth and a 0.1µF ceramic capacitor.
Specifications (measured at T
a
= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
UL60950-1 Certified
CSA C22.2 No. 60950-1-07 Certified
IEC/EN60950-1 Certified
EN55022 Compliant
E358085
DC/DC Converter
ECO-2
REV.: 2/2017 www.recom-power.com
Specifications (measured at T
a
= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) only with “/P” suffix continuous, automatic recovery
Isolation Voltage I/P to O/P
without suffix
with suffix “/H”
3kVDC / 1 second
4kVDC / 1 second
Isolation Capacitance 135pF max.
Isolation Resistance 10G min.
REGULATIONS
Parameter Condition Values
Output Voltage Accuracy ±5% max.
Line Voltage Regulation low line to high line, full load and 1%Vin ±1.2% typ.
Load Voltage Regulation 10% to 100% load ±5% typ. / ±10% max.
RKZ-xx2005D
Series
Tolerance Envelope
10
-5%
-0.5%
+5%
+10%
Typical Load Line
+4%
Vnom
50 100
Output Voltage
Load [%]
10
-5%
-1%
+5%
+10%
Typical Load Line
+5%
Vnom
50 100
Output Voltage
Load [%]
Efficiency vs. Load
Efficiency [%]
Load [%]
0
0
20
40
60
80
100
20 40 60 80 100
5Vin
12Vin
15Vin
24Vin
5Vout 20Vout
DC/DC Converter
Specifications (measured at T
a
= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
RKZ-xx2005D
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range free air convection, with derating -40°C to +100°C
Operating Humidity non-condensing 5% - 95% RH max.
Vibration MIL-STD-202G
MTBF according to MIL-HDBK-217F
+25°C
+85°C
1800 x 10
3
hours
560 x 10³ hours
ECO-3
REV.: 2/2017www.recom-power.com
100
80
60
40
20
0
-40 0 604020-20 100
90
85
12080
Output Power [%]
Ambient Temperature [°C]
Safe Operating Area
Derating Graph
(@ nominal Vin at chamber and free air convection)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety
SPCLVD1602031
IEC60950-1, 2nd Edition, 2005
EN60950-1, 2nd Edition, 2006
Information Technology Equipment, General Requirements for Safety E358085
UL60950-1, 1st Edition, 2007
CAN/CSA C22.2 No. 60950-1-07, 1st Edition, 2006
RoHs 2 RoHS 6/6, 2011/65/EU
EMI Compliance Condition Standard / Criterion
Information technology equipment - Radio disturbance characteristics -
Limits and methods of measurement
with external filter
EN55022, Class B
C1
C2
+V
IN
-V
IN
+V
OUT
Com
-V
OUT
L1
MODEL C1 C2 L1
RKZ-052005D 10µF
470pF, 4kVDC
4.7µH
RKZ-122005D 4.7µF 22µH
RKZ-152005D 4.7µF 22µH
RKZ-242005D 2.2µF 47µH
EMC filter suggestion for EN55022 Class B