CAUTIONS FOR USE
ASCTB246E 201302-T
CAUTIONS FOR USE
RT-3 UNIT RELAY
4-POINT TERMINAL
1. Never install modules (relays) into
this product other than those
designated. Doing so will cause
malfunction, breakdown, and
breakdown of the connected product.
2. If a unit is dropped be sure to check
its external appearance and
characteristics before using it.
3. The operation and return voltage
values when equipped with PA relays
are based on the relay terminals being
face down. (RT-3 Unit relay (PA type),
4-point Terminal)
4. Switching lifetime (PA relay)
This characteristic depends on the relay
and is effected by coil driving circuit, load
type, activation frequency, activation
phase, ambient conditions and other
factors.
Also, be especially careful of loads such
as those listed below.
1) When used for AC load-operating and
the operating phase is synchronous,
rocking and fusing can easily occur due
to contact shifting.
2) Frequent switching under load
condition
When high frequently switched under
load condition that can cause arc at the
contacts, nitrogen and oxygen in the air is
fused by the arc energy and HNO
3 is
formed. This can corrode metal materials.
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
5. Operating environment
1) Keep the product as far way as
possible from power cables, high tension
equipment, power equipment, equipment
with transmitting devices such as
amateur radios, or equipment which
generates a large switching surge.
2) The main unit is made of resin;
therefore, do not use it in areas where it
may come in contact with (or be exposed
to) organic solvents such as gasoline,
thinner, and alcohol, or strong alkaline
substances such as ammonia and
caustic soda.
3) Do not use the product in areas where
it may be exposed to flammable gases,
corrosive gases, excessive dust, or
moisture, or areas where it may be
subjected to strong vibration or shock.
6. Installing and removing the module
1) Firmly insert the module into the
socket with the terminals going in the
direction of the blade receptacles.
2) The module can be easily removed
using the removal key.
(1) Insert the removal key into the socket
slots.
(2) Pull the removal key up to remove the
module.
(3) Slide the removal key off of the
module.
7. Wiring and circuit configuration
1) Perform wiring according to the
internal schematic. Take care not to make
any mistakes.
In particular, with the RT-3 Unit relay (PA
relay type) and 4-point terminal, be
careful of the polarity on the output side
when equipped with AQZ10D (DC type).
Also, with the RT-3 Unit relay (Power
PhotoMOS type), be careful of the
polarity on the output side of the DC type
(RT3SP1-∗∗V for type equipped with
AQZ102).
2) We recommend the use of wire-
pressed terminals for connection to the
terminal portion.
• Example of applicable wire-pressed
terminal
3) When the load is inductive, limit spike
voltages generated from the load to less
than the maximum load voltage.
Typical circuits are shown below.
(1) Add a clamp diode to the load.
(2) Add an R-C snubber to the load.
(3) Add a varistor between the output
terminals.
4) Even if spike voltages generated from
the load are limited by a clamp diode or
R-C snubber, inductances in long circuit
wires will still create spike voltages.
Keep wires as short as possible to
minimize inductance.
Company
Name
Part Name
Applicable wire-
pressed terminal
J.S.T. Mfg
Co., Ltd.
1.25 to C3A 0.25 to 1.65mm
2
Output terminals
Load
Output terminals
Load or
DC only for AQZ10D
equipped type
Output terminals
Load or
DC only for AQZ10D
equipped type
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
CAUTIONS FOR USE
ASCTB246E 201302-T
TERMINAL BLOCK
We recommend using wire-pressed terminals for connection to the terminal portion.
ACCESSORIES
8. Installation
1) Perform mounting hole cutout
according to the panel cutout drawings.
2) When installing the unit on a DIN rail,
use the DIN rail locking lever on the side
of the unit. Installation is accomplished by
simply fitting the unit onto the rail and
pressing gently.
3) To remove the unit from the DIN rail,
use a flat head screwdriver to pull out the
DIN rail locking lever.
9. Transporting and storage
1) If the product is subjected to extreme
vibration while being transported, the
relays may become detached, the lead
may become bent, and the unit may
become damaged. Handle the carton
and case with care.
2) If the product is stored in an extremely
adverse environment, visible defects and
deterioration of performance
characteristics may result. We
recommend the following storage
conditions.
•Temperature: 5 to 30°C 41 to 86°F
Humidity: Max. 60% R.H.
•Environment: No hazardous
substances such as sulfurous acid
gases and little dust.
10. When equipped with Power
PhotoMOS voltage drive type [RT-3
Unit relay (PA relay type), 4-point
Terminal]
Since the Power PhotoMOS voltage
sensitive type does not require the
current-controlling resistance on the input
side, it can be used together with PA
relays on RT-3 unit relay (PA relay type)
or RT-2 relay terminals.
When connecting Power PhotoMOS
voltage sensitive types, since it will be a
close connection, it will be necessary to
be careful of load currents. Be sure to
refer to the information given regarding
“Load currents vs ambient temperature
characteristics” in the precautions given
for use of 4-point terminals.
DIN rail locking lever
DIN rail
1
2
3
First push in
the DIN rail
locking lever.
Hook the holders on the
unit over the DIN rail.
Press the unit onto
the DIN rail.
1
2
3
Insert the tip of the flat head screwdriver
into the slot in the DIN rail locking lever.
Move the
screwdriver in
the direction of
the arrows, and
pull out the lever.
Remove the unit from
the DIN rail.
Applicable electrical wire: 0.25 to 1.65 mm
2
.01 to .065 inch
Applicable wire-pressed terminals (mm inch)
Company Name Part Name Part Name
J.S.T. Mfg Co., Ltd. 1.25 to C3A 1.25 to 3
NICHIFU 1.25Y to 3N 1.25 to 3
Nippon Tanshi Co., Ltd. VD1.25 to 3L R1.25 to 3
3 min.
5.8 max.
4.5 min.4
.118 min.
.228 max.
.177 min..157
3 dia. min.
5.8 max.
4.5 min.4
.118 dia. min.
.228 max.
.117 min..157
Short circuit plate for RT-3 Unit relay
Use when you want to bridge terminals.
< With insulator >
External dimensions (mm inch)
< Without insulator >
External dimensions (mm inch)
AY3802
13.8
17.8
5.8
±0.1
7.62
±0.3
.300
±.012
+0.5
1
28
+.020
.039
1.102
8
+0
3
.315
3.1
±0.1
.228
±.004
.122
±.004
R
28.7
0.5
1.5 to 2.5
+0
.118
.543
.701
1.130
.020
.059 to .098
AY3803
13
17
5.8
±0.1
7.62
±0.3
.300
±.012
26.5
3.1
±0.1
.228
±.004
.122
±.004
R
28.7
0.5
.512
.669
1.043
1.130
.020
General tolerance: ±0.5 ±.020 General tolerance: ±0.5 ±.020

AY3802

Mfr. #:
Manufacturer:
Panasonic
Description:
SHORTING BAR 4 POS FOR RELAYS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet