MEA1D4815SC

MEA1 Series
1kVDC Isolated 1W Dual Output DC/DC Converters
KDC_MEA1.C06 Page 1 of 8
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
 
SELECTION GUIDE
Order Code
Nominal Input
Voltage
Output
Voltage
Output Current
Input Current at
Rated Load
Load Regulation
(Typ)
Load Regulation
(Max)
Ripple & Noise
(Typ)
1
Ripple & Noise
(Max)
1
Efficiency (Min.)
Efficiency (Typ.)
Isolation
Capacitance
MTTF
2
Package Style
V V mA mA % mVp-p % % pF kHrs
MEA1D0505SC 5 ±5 ±100 233 4.8 5.4 12 25 82 85 53 3663
SIP
MEA1D0509SC 5 ±9 ±56 228 3.7 4.5 8 20 84 86.5 51 3291
MEA1D0512SC 5 ±12 ±42 228 4 5 6 20 84 87 45 2860
MEA1D0515SC 5 ±15 ±33 225 3.8 4.5 6 20 84 87 46 2374
MEA1D1205SC 12 ±5 ±100 98 3.5 4 9 20 81 85 44 3352
MEA1D1209SC 12 ±9 ±56 95 2.5 3 7 20 83 86.5 61 3083
MEA1D1212SC 12 ±12 ±42 93 2.6 3.5 6 20 85 89 88 2701
MEA1D1215SC 12 ±15 ±33 94 2.2 3 5 20 84 88 78 2264
MEA1D1505SC 15 ±5 ±100 78 3 3.5 8 20 80 84 40
MEA1D1509SC 15 ±9 ±56 76 2.1 2.5 7 20 82 87 65
MEA1D1512SC 15 ±12 ±42 76 2 2.5 5 20 83 87.5 75
MEA1D1515SC 15 ±15 ±33 75 2 2.5 5 20 85 89.5 104
MEA1D2405SC 24 ±5 ±100 49 2.8 3.5 9 20 81 84.5 47
MEA1D2409SC 24 ±9 ±56 47 1.8 2.5 7 20 84 87.5 80
MEA1D2412SC 24 ±12 ±42 47 1.6 2.5 4 20 84 87 85
MEA1D2415SC 24 ±15 ±33 47 1.5 2.5 3 20 85 88.5 106
MEA1D4805SC 48 ±5 ±100 26 2.6 4 14 25 77 80 44
MEA1D4809SC 48 ±9 ±56 25 1.6 3 8 20 79 82 72
MEA1D4812SC 48 ±12 ±42 25 1.6 3 7 20 78 83 91
MEA1D4815SC 48 ±15 ±33 25 1.3 2.5 6 20 80 83.5 109
MEA1D0505DC 5 ±5 ±100 232 5 6.2 12 25 82 85 52
DIP
MEA1D0509DC 5 ±9 ±56 227 3.9 5 9 20 84 86.7 49
MEA1D0512DC 5 ±12 ±42 226 4.2 5.3 7 20 84 87 47
MEA1D0515DC 5 ±15 ±33 224 4.1 5.3 6 20 84 87.5 46
MEA1D1205DC 12 ±5 ±100 97 3.6 4.5 9 20 81 84.5 43
MEA1D1209DC 12 ±9 ±56 95 2.6 3.5 7 20 83 86.5 64
MEA1D1212DC 12 ±12 ±42 93 2.7 3.5 6 20 85 89 89
MEA1D1215DC 12 ±15 ±33 94 2.3 3 6 20 84 88 76
MEA1D1505DC 15 ±5 ±100 78 3.1 4 9 20 80 84 42
MEA1D1509DC 15 ±9 ±56 76 2.2 3 6 20 82 87 50
MEA1D1512DC 15 ±12 ±42 76 2 2.7 6 20 83 87.5 77
MEA1D1515DC 15 ±15 ±33 75 2 2.7 6 20 85 89.5 106
MEA1D2405DC 24 ±5 ±100 49 2.8 4 10 20 81 84.5 47
MEA1D2409DC 24 ±9 ±56 48 2 3.8 8 20 84 87 77
MEA1D2412DC 24 ±12 ±42 47 1.6 2.5 6 20 84 87 83
MEA1D2415DC 24 ±15 ±33 47 1.5 2.3 6 20 85 88 100
1. See Ripple & Noise characterisation method.
2. Calculated using MIL-HDBK-217F FN2 with nominal input voltage at full load.
All specifications typical at T
A=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
UL 60950 recognized
RoHS compliant
Typical efficiency to 89.5%
Power density to 0.85W/cm
3
Wide temperature performance at full
1 Watt load, –40°C to 85°C
UL 94V-0 package material
No heatsink required
Industry standard pinout
Power sharing on output
5V,12V, 15V, 24V, & 48V input
5V, 9V, 12V, & 15V output
Fully encapsulated with toroidal
magnetics
No external components required
No electrolytic or tantalum capacitors
PRODUCT OVERVIEW
The MEA series is the new high performance
version of our 1W NMA series. The MEA series
is more efficient and offers improved regulation
performance ≤5% for applications where a wide
output voltage variation can not be tolerated. They
are ideally suited for providing dual rail supplies
with the added benefit of galvanic isolation to
reduce switching noise. All of the rated power
may be drawn from a single output providing the
total load does not exceed 1 watt.
MEA1 Series
1kVDC Isolated 1W Dual Output DC/DC Converters
KDC_MEA1.C06 Page 2 of 8
www.murata-ps.com/support
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range
Continuous operation, 5V input types 4.5 5 5.5
V
Continuous operation, 12V input types 10.8 12 13.2
Continuous operation, 15V input types 13.5 15 16.5
Continuous operation, 24V input types 21.6 24 26.4
Continuous operation, 48V input types 43.2 48 52.8
Reflected ripple current
5V input types 4 12
mA p-p
12V input types 4 12
15V input types 3 10
24V input types 3 10
48V input types 22 35
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated Power
T
A=-40°C to 85°C
1W
Voltage Set Point Accuracy See tolerance envelope
Line regulation High V
IN to low VIN 1.05 1.1 %/%
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation test voltage Flash tested for 1 second 1000 VDC
Resistance Viso= 1000VDC 10 GΩ
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Switching frequency
MEA1D05xxxC, MEA1D1212xC, MEA1D1515xC 65
kHz
MEA1D1205xC, MEA1D1209xC, MEA1D1215xC, MEA1D1505xC,
MEA1D1509xC, MEA1D1512xC, MEA1D24xxxC
85
MEA1D48xxxC 60
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specification All output types -40 85
°CStorage -50 125
Case Temperature above ambient 20
Cooling Free air convection
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1mm from case for 10 seconds 260°C
Input voltage VIN, 5Vin types 7V
Input voltage VIN, 12Vin types 15V
Input voltage VIN, 15Vin types 18V
Input voltage VIN, 24Vin types 28V
Input voltage VIN, 48Vin types 54V
MEA1 Series
1kVDC Isolated 1W Dual Output DC/DC Converters
KDC_MEA1.C06 Page 3 of 8
www.murata-ps.com/support
TEMPERATURE DERATING GRAPH TOLERANCE ENVELOPE
The voltage tolerance envelope shows typical load regulation characteristics for this
product series. The tolerance envelope is the maximum output voltage variation due
to changes in output loading.
Output Load Current (%)
egatloV tup
tuO
VNOM
5%
0%
-4%
2%
T
ypical Load Line
100
75
50
25
10
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MEA1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MEA1 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The MEA1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The MEA1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85°C and/or case temperature
limit of 130°C (case temperature measured on the face opposite the pins). File number E151252 applies.
The MEA1 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
MEA1D05xxxC: 1A
MEA1D12xxxC: 0.375A
MEA1D15xxxC: 0.375A
MEA1D24xxxC: 0.2A
MEA1D48xxSC: 0.1A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
150100
50
0
-40
0
0.5
1.0
1.5
Safe Operating Area
85°C
Ambient Temperature (°C)
Output Power (W)

MEA1D4815SC

Mfr. #:
Manufacturer:
Murata Power Solutions
Description:
Isolated DC/DC Converters 1W 48Vin +/-15Vout +/-33mA 1kVDC SIP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union