150~200W Constant Current Mode LED Driver
ELG-200-C series
SPECIFICATION
MODEL
RATED CURRENT
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
SET UP TIME
Note.4
VOLTAGE RANGE Note.3
FREQUENCY RANGE
POWER FACTOR
(Typ.)
EFFICIENCY (Typ.)
AC CURRENT(Typ.)
INPUT
INRUSH CURRENT
(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER TEMPERATURE
OVER VOLTAGE
(Please refer to "STATIC CHARACTERISTIC" )
section
47 ~ 63Hz
PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load≧≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
1.8A / 115VAC 1.0A / 230VAC 1.0A/277VAC
<0.75mA / 277VAC
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
ENVIRONMENT
EMC EMISSION
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
CURRENT TOLERANCE
±5.0%
CONSTANT CURRENT REGION
Note.2
THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
TOTAL HARMONIC DISTORTION
OPEN CIRCUIT VOLTAGE
(max.)
Adjustable for A/AB-Type only (via built-in potentiometer)
COLD START 65A(twidth= s measured at 50% Ipeak)/230VAC680 Per NEMA 410μ;
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
Tcase=-40 ~ +85 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)℃
MAX. CASE TEMP.
Tcase=+85℃
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:6KV,Line-Line:4KV)
;EAC TP TC 020
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current ℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 85 or less.℃
7. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
8. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
CURRENT RIPPLE 5.0% max. @rated current
100 ~ 305VAC 142 ~ 431VDC
No load power consumption <0.5W for Blank / A / Dx / D2-Type
NO LOAD / STANDBY
POWER CONSUMPTION
Standby power consumption <0.5W for B / AB / DA-Type
ELG-200-C700
ELG-200-C1050
ELG-200-C1400
ELG-200-C1750
ELG-200-C2100
700mA
1050mA
1400mA
1750mA
2100mA
200.2W
199.5W
198.8W
199.5W
201.6W
142 ~ 286V
95 ~ 190V
71 ~ 142V
57 ~ 114V
48 ~ 96V
300V
200V
160V
120V
105V
350 ~ 700mA
525 ~ 1050mA
700 ~ 1400mA
875 ~ 1750mA
1050 ~ 2100mA
93%
93%
92%
92%
92%
315 ~ 370V
205 ~ 250V
160 ~ 180V
125 ~ 150V
105 ~ 130V
2**344 71 7.5 mm (L*W*H)
1.22Kg; 12pcs /15.2kg / 0.72CUFT
800ms/115VAC, 500ms/230VAC
Compliance to EN55015,EN61000-3-2 Class C (@load 50%) ; EN61000-3-3; GB17625.1, GB17743≧
;EAC TP TC 020
958.9K hrs min. Telcordia SR-332 (Bellcore) 235Khrs min. MIL-HDBK-217F (25 )℃
UL8750 independent, EN62384;(type”HL”), CSA C22.2 No. 250.13-12;EN/AS/NZS 61347-1,EN/AS/NZS 61347-2-13
GB19510.14,GB19510.1; ;IP65 or IP67 approvedEAC TP TC 004;BIS IS15885(for 700A only)
200VAC ~ 305VAC
100VAC ~ 180VAC
150.5W
150.15W
149.8W
150.5W
151.2W
DALI STANDARDS
Compliance to IEC62386-101, 102, 207 for DA-Type only
File Name:ELG-200-C-SPEC 2018-05-29