Translation of the original operating instructions
4.3 Connecting the cables
The device has external leads.
; First connect the "PE" (protective earth).
Connect the cables according to your application. When doing so,
observe Chapter 4.4 Connection diagram.
Item no. 10294-5-9970 · ENU · Change 89436 · Approved 2016-08-25 · Page 7 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
G2E180-EH03-01
Translation of the original operating instructions
4.4 Connection diagram
U1 blue
Z brown
U2 black
PE green/yellow
Item no. 10294-5-9970 · ENU · Change 89436 · Approved 2016-08-25 · Page 8 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
G2E180-EH03-01
Translation of the original operating instructions
4.5 Checking connections
; Ensure isolation from supply (all phases).
; Make sure a restart is impossible
; Check the cables for proper fit.
4.6 Switching on the device
The device may only be switched on if it has been installed properly and
in accordance with its intended use, including the required safety
mechanisms and professional electrical hookup. This also applies for
devices which have already been equipped with plugs and terminals or
similar connectors by the customer.
WARNING
Hot motor housing
Risk of fire
Ensure that no combustible or flammable materials are
located close to the blower.
; Before switching on, check the device for visible external damage
and make sure the protective devices are functional.
; Check the fan's air flow paths for foreign matter and remove any
foreign matter found.
; Apply the nominal supply voltage.
NOTE
Damage to the device from vibration
Bearing damage, shorter service life
Low-vibration operation of the fan must be ensured over the
entire speed control range. #Severe vibration can arise for
instance from inexpert handling, transportation damage and
resultant imbalance or be caused by component or structural
resonance. #Speed ranges with excessively high vibration
levels and possibly resonant frequencies must be
determined in the course of fan commissioning. #Either run
through the resonant range as quickly as possible with
speed control or find another remedy.# Operation with
excessively high vibration levels can lead to premature
failure.
4.7 Switching off the device
; Disconnect the device from the power supply at the supply line's
main switch.
; When disconnecting, be sure to disconnect the ground connection last.
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
Do not perform any repairs on your device. Send the device to ebm-
papst for repair or replacement.
WARNING
Live terminals and connections even with device
switched off
Electric shock
Wait five minutes after disconnecting the voltage at all poles
before opening the device.
CAUTION
Electric charge on capacitor after device is switched off
Electric shock, risk of injury
Discharge the capacitors before working on the device.
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Risk of injury
Keep out of the device's danger zone.
When working on the device, switch off the line voltage
and ensure that it cannot be switched back on.
Wait until the device comes to a stop.
If the device is out of use for some time, e.g. when in storage,
we recommend switching it on for at least two hours to allow
any condensation to evaporate and to move the bearings.
Malfunction/fault Possible cause Possible remedy
Impeller not
running smoothly
Imbalance in rotating
parts
Clean the device;
replace it if imbalance
persists after cleaning.
Make sure no
weight clips are
removed during
cleaning.
Motor not turning Mechanical blockage Switch off, isolate
from supply and
remove mechanical
blockage.
Line voltage faulty Check line voltage,
restore power supply.
Faulty connection Isolate from supply,
correct connection;
see connection
diagram.
Thermal overload
protector activated
Allow motor to cool
off, locate and rectify
cause of error,
release restart lockout
if necessary
Impermissible point of
operation
Check point of
operation
Motor
overtemperature
Ambient temperature
too high
Reduce ambient
temperature if possible
Deficient cooling Improve cooling
Item no. 10294-5-9970 · ENU · Change 89436 · Approved 2016-08-25 · Page 9 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

G2E180-EH03-01

Mfr. #:
Manufacturer:
ebm-papst
Description:
Blowers AC Centrifugal Blower
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet