Data Sheet ADuM5000
Rev. B | Page 5 of 16
PACKAGE CHARACTERISTICS
Table 5.
Parameter Symbol Min Typ Max Unit Test Conditions
RESISTANCE AND CAPACITANCE
Resistance (Input-to-Output)
R
10
Ω
Capacitance (Input-to-Output)
C
2.2 pF f = 1 MHz
Input Capacitance
2
C
4.0 pF
IC Junction-to-Ambient Thermal Resistance θ
JA
45 °C/W Thermocouple is located at the center of
the package underside; test conducted
on a 4-layer board with thin traces
3
THERMAL SHUTDOWN
Thermal Shutdown Threshold TS
150 °C T
rising
Thermal Shutdown Hysteresis TS
20 °C
1
This device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
3
Refer to the Power Considerations section for thermal model definitions.
REGULATORY INFORMATION
The ADuM5000 is approved by the organizations listed in Table 6. Refer to Table 11 and the Insulation Lifetime section for more
information about recommended maximum working voltages for specific cross isolation waveforms and insulation levels.
Table 6.
UL CSA VDE (Pending)
Recognized under 1577 component
recognition program
1
Approved under CSA Component Acceptance
Notice #5A
Certified according to IEC 60747-5-2 (VDE 0884,
Part 2):2003-01
2
Single protection, 2500 V rms isolation
voltage
Testing was conducted per CSA 60950-1-07
and IEC 60950-1, 2nd Edition at 2.5 kV rated
voltage
Basic insulation at 400 V rms (566 V peak)
working voltage
Reinforced insulation at 250 V rms (353 V peak)
working voltage
Basic insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM5000 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec (current leakage detection limit = 5 µA).
2
In accordance with IEC 60747-5-2 (VDE 0884, Part 2):2003-01, each ADuM5000 is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial
discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884, Part 2):2003-01.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 7.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.0 mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 7.6 mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Distance (Internal Clearance) 0.017
min
mm Distance through the insulation
Tracking Resistance (Comparative Tracking Index)
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)