Data Sheet ADuM5000
Rev. B | Page 5 of 16
PACKAGE CHARACTERISTICS
Table 5.
Parameter Symbol Min Typ Max Unit Test Conditions
RESISTANCE AND CAPACITANCE
Resistance (Input-to-Output)
1
R
I-O
10
12
Capacitance (Input-to-Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Ambient Thermal Resistance θ
JA
45 °C/W Thermocouple is located at the center of
the package underside; test conducted
on a 4-layer board with thin traces
3
THERMAL SHUTDOWN
Thermal Shutdown Threshold TS
SD
150 °C T
J
rising
Thermal Shutdown Hysteresis TS
SD-HYS
20 °C
1
This device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
3
Refer to the Power Considerations section for thermal model definitions.
REGULATORY INFORMATION
The ADuM5000 is approved by the organizations listed in Table 6. Refer to Table 11 and the Insulation Lifetime section for more
information about recommended maximum working voltages for specific cross isolation waveforms and insulation levels.
Table 6.
UL CSA VDE (Pending)
Recognized under 1577 component
recognition program
1
Approved under CSA Component Acceptance
Notice #5A
Certified according to IEC 60747-5-2 (VDE 0884,
Part 2):2003-01
2
Single protection, 2500 V rms isolation
voltage
Testing was conducted per CSA 60950-1-07
and IEC 60950-1, 2nd Edition at 2.5 kV rated
voltage
Basic insulation at 400 V rms (566 V peak)
working voltage
Reinforced insulation at 250 V rms (353 V peak)
working voltage
Basic insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM5000 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec (current leakage detection limit = 5 µA).
2
In accordance with IEC 60747-5-2 (VDE 0884, Part 2):2003-01, each ADuM5000 is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial
discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884, Part 2):2003-01.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 7.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.0 mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 7.6 mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Distance (Internal Clearance) 0.017
min
mm Distance through the insulation
Tracking Resistance (Comparative Tracking Index)
CTI
>175
V
DIN IEC 112/VDE 0303 Part 1
Isolation Group
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
ADuM5000 Data Sheet
Rev. B | Page 6 of 16
IEC 60747-5-2 (VDE 0884, PART 2):2003-01 INSULATION CHARACTERISTICS
This power module is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured
by protective circuits. The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884, Part 2):2003-01 approval.
Table 8.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input-to-Output Test Voltage
Method b1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V peak
Method a V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1 896 V peak
After Input and/or Safety Test
Subgroup 2 and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 672 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 sec V
TR
4000 V peak
Safety-Limiting Values Maximum value allowed in the event of a failure
(see Figure 2)
Case Temperature T
S
150 °C
Side 1 I
DD1
Current I
S1
555 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Thermal Derating Curve
0
100
200
300
400
500
600
0 50 100 150 200
AMBIENT TEMPERATURE (°C)
SAFE OPERATING V
DD1
CURRENT (mA)
07539-002
Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Values on Case Temperature, per DIN EN 60747-5-2
RECOMMENDED OPERATING CONDITIONS
Table 9.
Parameter Symbol Min Max Unit Comments
TEMPERATURE
1
Operating Temperature T
A
−40 +105 °C
SUPPLY VOLTAGES
2
Each voltage is relative to its respective ground
V
DD1
at V
SEL
= 0 V V
DD1
2.7 5.5 V
V
DD1
at V
SEL
= 5 V V
DD1
4.5 5.5 V
1
Operation at 105°C requires reduction of the maximum load current as specified in Table 10.
2
Each voltage is relative to its respective ground.
Data Sheet ADuM5000
Rev. B | Page 7 of 16
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 10.
Parameter Rating
Storage Temperature (T
ST
) −55°C to +150°C
Ambient Operating Temperature (T
A
) −40°C to +105°C
Supply Voltages (V
DDx
, V
ISO
)
1
−0.5 V to +7.0 V
Input Voltage (RC
SEL
, RC
IN
, V
SEL
)
1, 2
−0.5 V to V
DDI
+ 0.5 V
Output Voltage (RC
OUT
)
1, 2
−0.5 V to V
DDO
+ 0.5 V
Average Total Output Current
3
I
ISO
100 mA
Common-Mode Transients
4
−100 kV/µs to +100 kV/µs
1
Each voltage is relative to its respective ground.
2
V
DDI
and V
DDO
refer to the supply voltages on the input and output sides of a
given channel, respectively. See the PCB Layout section.
3
See Figure 2 for maximum rated current values for various temperatures.
4
Refers to common-mode transients across the isolation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause
latch-up or permanent damage.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 11. Maximum Continuous Working Voltage
1
Parameter Max Unit Reference Standard
AC Voltage
Bipolar Waveform
424
V peak
50-year minimum
lifetime
Unipolar Waveform
Basic Insulation 600 V peak
Maximum approved
working voltage per
IEC 60950-1
Reinforced Insulation 353 V peak Maximum approved
working voltage per
IEC 60950-1
DC Voltage
Basic Insulation 600 V peak
Maximum approved
working voltage per
IEC 60950-1
Reinforced Insulation 353 V peak Maximum approved
working voltage per
IEC 60950-1
1
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
ESD CAUTION