D-SERIES INCLINOMETER
SENSOR SOLUTIONS /// D-Series Inclinometer Rev.5 02/2017
Page 2
PERFORMANCE SPECIFICATIONS
Conditions Min Type Max Unit
Measurement range -5 (-15,-30) +5(+15,+30) °
Resolution 0.001 0.005 °
Accuracy,digital,analogue (absolute)
Ta = +25°C 0.04 °
Accuracy,digital,analogue (absolute)
Ta = - 40°C to 85°C 0.15 (0.3,0.8) °
Offset temperature drift error Ta = - 40°C to 85°C 0.06 °
Noise RMS 0.001 °
Frequence responce 2 3 Hz
Power supply 10 30 VDC
Operation temperature range -40 +85 °C
Storage temperature range -40 +85 °C
Weight 290 g
Dimensions W x D x H 84 x 70 x 46 mm
Unit with RS 232 interface and analogue output signal
Transmission rate, programmable 0.1 10 16 Hz
Baud rate, programmable 2.4 9.6 57.6 kB
Current output 20 4 mA
Voltage output 0.5 4.5 V
PWM output 1 KHz 20 80 %
Switch output,programmable Step 0.1 °
Current consumption 30 40 mA
Unit with CANopen interface
Baud rate, programmable 0.02 0.25 1 MBaud
Code Binary -
Interface CAN according to CAL -
Current consumption 50 90 mA