SCA121T Series
Murata Electronics Oy Subject to changes 5/5
www.muratamems.fi Doc. nr. 82 1274 00 Rev.A
ySensitivit
out
=
Straight line conversion equation:
Where: Sensitivity = 70mV/° with SCA121T-D07 or Sensitivity= 35mV/° with SCA121T-D03 and
SCA121T-D05
Straight line conversion error [°]
2.3 Ratiometric Output
Ratiometric output means that the zero offset point and sensitivity of the sensor are proportional to
the supply voltage. If the SCA121T-D05 supply voltage is fluctuating the SCA121T-D05 output will
also vary. When the same reference voltage for both the SCA121T-D05 sensor module and the
measuring part (A/D-converter) is used, the error caused by reference voltage variation is
automatically compensated for.
3 Mechanical Specifications
Cable length: -D03,-D07 30cm
-D05 110cm
Cable type: UL/CSA listed, PUR black
Cable diam.: 6±0.2mm
Leads: 5 x 0.14mm
2
Total weight: Approx. 60 grams
Protection class: IP66
Housing: Zinc casting with passivation
Mounting: The sensor module is to be mounted on a flat and smooth surface
with 2 screws, dimension M4. Mounting torque 5 ±1Nm
3.1 Sensor dimensions
Figure 2. Mechanical dimensions of the SCA121T (Dimensions in mm)