VI-AIM-C1

VI-AIM™ Rev 2.9 vicorpower.com
Page 1 of 4 06/2017 800 927.9474
Alternating Input Module
Universal AC Input Front End Module
VI-AIM™
Actual size:
2.28 x 2.4 x 0.5in
57,9 x 61,0 x 12,7mm
VI-AIM Input Voltage Compatible Notes
DC-DC Converter
85 – 132 Vac VI-x5x-xx Used with a 100 – 200V
IN
converter
180 – 264 Vac VI-x6x-xx Used with a 200 – 400V
IN
converter
85 – 264 Vac VI-x7x-xx Used with a 100 – 375V
IN
converter
Parameter Rating Unit Notes
Maximum value of hold-up capacitance 1200 µF
Thermal resistance 0.4 °C/Watt Baseplate-to-sink
Operating temperature 55 to +100 °C M-Grade
Storage temperature 65 to 100 °C M-Grade
Transient surge withstand
Common mode
1.2/50µS, 2kV pulse, 2 joules EN61000-4-5
0 to 360 degree phase angle IEC 801-5
Normal mode
1.2/50µS, 1kV pulse, 2 joules
With external MOV
0 to 360 degree phase angle
Features & Benefits
RoHS compliant (VE versions)
Universal input: 85 – 264V
AC
Output power: 250W
Operating temperature: 100°C
Efficiency: 97%
Integral EMI filtering
Input transient protection
Inrush limiting
CE Marked
Product Highlights
The AIM (Alternating Input Module) is an
AC front-end module which interfaces
directly with worldwide AC mains. The AIM
provides line rectification, EMI/RFI filtering,
transient protection and inrush limiting in a
half brick package measuring
2.28” x 2.4” x 0.5.
The AIM is used in conjunction with Vicor
VI-200 or VI-J00 DC-DC converters to
realize a universal AC input, high-density,
low-profile switching power supply with
outputs from 1 – 95V
DC
and a total
power rating up to 200W. An external
capacitor is used to satisfy system hold-
up requirements. Internal EMI filtering
meets EN55022 and FCC Part 15, Class A
emissions limits.
Absolute Maximum Ratings
VI - AIM - E 1
*
Part Numbering
* For Mega Module packaging option add an L before the product name.
Example: Vx-LAIM-xx
Product Grade Temperatures (°C)
Grade Operating Storage
E =
-
10 to +100
-
20 to +100
C =
-
25 to +100
-
40 to +100
I =
-
40 to +100
-
55 to +100
M =
-
55 to +100
-
65 to +100
AC Input Module
Product NameCompliance
VI = Non RoHS
VE = RoHS
VI-AIM™ Rev 2.9 vicorpower.com
Page 2 of 4 06/2017 800 927.9474
VI-AIM™
INPUT SPECIFICATIONS
Parameter Min Typ Max Unit Notes
AC line input 85 – 264
[1]
V
AC
No strapping; no damage below low line
47 – 440 Hz
Inrush current <40A at peak line (264
V
RMS
)
[1]
Dependent upon input range of compatible DC-DC converter.
OUTPUT SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Output voltage 120 – 373 V
DC
Peak of AC line
Output power 250 W Delivered to converter(s)
Hold-up time Application specific A function of external capacitance and power
Efficiency 97% %
SAFETY SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Dielectric withstand
Input to output None Provided by DC-DC converter
Input/output to baseplate 1,500 V
RMS
GENERAL SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Size 2.28” x 2.4” x 0.5” (57,9 x 61,0 x 12,7) in (mm) Mega Module, SlimMod and FinMod packages available
Weight 3.0 (85) Ounces (Grams)
AGENCY APPROVALS
Safety Standards Agency Markings Notes
Conducted EMI/RFI
VDE 0871/FCC Part 15, Class A With compatible DC-DC converter modules
EN55022, Class A External 0.47µF capacitor required
UL1950, CSA 22.2-950, EN60950
Specifications
(typical at T
BP
= 25°C, nominal line and 75% load, unless otherwise specified)
Storage
Vicor products, when not installed in customer units, should be stored in ESD safe packaging in accordance with ANSI/ESD S20.20,
“Protection of Electrical and Electronic Parts, Assemblies and Equipment” and should be maintained in a temperature controlled factory/
warehouse environment not exposed to outside elements controlled between the temperature ranges of 15°C and 38°C. Humidity shall not
be condensing, no minimum humidity when stored in an ESD compliant package.
VI-AIM™ Rev 2.9 vicorpower.com
Page 3 of 4 06/2017 800 927.9474
VI-AIM™
Mechanical Diagram
Universal
AC In
AIM
GATE OUT
PAR
GATE IN
+OUT
–OUT
L2/N
NC
NC
L1
0.47µF
–OUT
–S
TRIM
+S
+OUT
+IN
GATE
IN
GATE
OUT
–IN
VI-200/J00
Driver
Load
F2
0.01µF (Two 4,700pF)
Y-Rated Capacitors
0.01µF (Two 4,700 pF)
Y-Rated Capacitors
0.01µF Ceramic
0.01µF Ceramic
C1
[a]
F1
[a]
Consult factory or refer to Selecting Capacitors for AIM Modules on page 34 of the VI-200 and VI-J00 Design Guide .
Z1: MOV Part #30076
Fuse 1: 6.3A/250V (IEC 5X20mm) Buss GDB-6.3 or 7A / 250V (3AG 1/4" x 1 1/4") Littlefuse 314-007
Fuse 2: For VI-X7X-XX — Buss PC-Tron 2.5A (250V)
For VI-X6X-XX — Buss PC-Tron 3A (250V)
For VI-X5X-XX — Buss PC-Tron 5A
Z1
VI-AIM Block Diagram
VI-AIM Connection Diagram, Typical Application
EMI
Filter
10V
U2
U1
OC
OV
V
REF
2
V
REF
1
+OUT
–OUT
GATE IN
GATE OUT
PARALLEL
Q1
Q2
Level
Shift
D2
D1
C2
L1
L2/N
5
6
7
8
9
4
3
2
1
.080 Dia (2) places
Solder plate
over copper alloy
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
.01
Aluminum Base
Product ID
this surface
Function
L1
L2/N
+OUT
Parallel
Gate Out
–OUT
Pin #
1
2
3
4
5
6
7
8
9
FULL R
+.030
-.000
(5,6) Min.
.30 Min.
1.75 Max.
2.40
2.28
.12
.50
1.90
.65
(16,5)
.49
(12,4)
.30.015
.15
2.10
(53,4)
1.30
.40
(10,2)
.35 .015
(8,9)(0,38)
1.40
(35,6)
1.00
(25,4)
.70
(17,8)
NC
NC
Gate In
VI-AIM Mechanical
VI-AIM
(57,9)
(33,0)
(7,6)(0,38)
(3,8)
.15
(3,8)
(48,3)
(3,0)
.22
(12,7)
(0,76)
(0)
(7,6)
(61,0)
(44,4)

VI-AIM-C1

Mfr. #:
Manufacturer:
Vicor
Description:
FRONT END MODULE 9 PIN HALF BRIC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet